16-8
IM 765501-01E
Command Function Page
:SPACing? Queries the sweep mode (linear or log) of the current sweep. 16-21
:STARt <Current>|MINimum|MAXimum
Sets the start value of the current sweep. 16-21
:STARt? [MINimum|MAXimum]Queries the start value of the current sweep. 16-21
:STOP <Current>|MINimum|MAXimum
Sets the stop value of the current sweep. 16-22
:STOP? [MINimum|MAXimum] Queries the stop value of the current sweep. 16-22
:STEP <Current>|MINimum|MAXimum
Sets the step value of the current sweep (linear sweep). 16-22
:STEP? [MINimum|MAXimum] Queries the step value of the current sweep (linear sweep). 16-22
:POINts <Integer>|MINimum|MAXimum
Sets the step count of the current sweep (log sweep). 16-22
:POINts? [MINimum|MAXimum]
Queries the step count of the current sweep (log sweep). 16-22
:ZERO
:IMPedance HIGH|LOW Sets the zero source impedance (high or low) for generating current. 16-22
:IMPedance? Queries the zero source impedance (high or low) for generating current. 16-22
:OFFset <Current> Sets the zero source offset value for generating current. 16-22
:OFFset? Queries the zero source offset value for generating current. 16-22
Sweep Commands (SWEep Group)
:SWEep
:TRIGger Starts the sweep operation. 16-23
:COUNt <Integer>|INFinity|MINimum|MAXimum
Sets the sweep repeat count. 16-23
:COUNt? [MINimum|MAXimum] Queries the sweep repeat count. 16-23
:LAST KEEP|RETurn Sets the sweep termination mode (keep level or return to initial level). 16-23
:LAST? Queries the sweep termination mode (keep level or return to initial level). 16-23
Measurement Commands (SENSe Group)
:SENSe
[:STATe] 1|0|ON|OFF Sets the measurement state (ON or OFF). 16-24
[:STATe]? Queries the measurement state (ON or OFF). 16-24
:FUNCtion VOLTage|CURRent|RESistance
Sets the measurement function (voltage, current, or resistance). 16-24
:FUNCtion? Queries the measurement function (voltage, current, or resistance). 16-24
:RANGe
:AUTO 1|0|ON|OFF Sets the measurement auto range (ON or OFF). 16-24
:AUTO? Queries the measurement auto range (ON or OFF). 16-24
:ITIMe <Time>|PLC|MINimum|MAXimum|UP|DOWN
Sets the integration time. 16-24
:ITIMe? [PLC|MINimum|MAXimum] Queries the integration time. 16-24
:DELay <Time>|MINimum|MAXimum
Sets the measurement delay. 16-24
:DELay? [MINimum|MAXimum] Queries the measurement delay. 16-24
:AZERo
[:STATe] 1|0|ON|OFF Sets the auto zero state (ON or OFF). 16-25
[:STATe]? Queries the auto zero state (ON or OFF). 16-25
:EXECute Executes auto zero. 16-25
:AVERage
[:STATe] 1|0|ON|OFF Sets the average state (ON or OFF). 16-25
[:STATe]? Queries the average state (ON or OFF). 16-25
:MODE BLOCk|MOVing Sets the average mode (block or moving average). 16-25
:MODE? Queries the average mode (block or moving average). 16-25
:COUNt <Integer>|MINimum|MAXimum
Sets the average count. 16-25
16.2 Commands