EasyManuals Logo

YOKOGAWA 765501 User Manual

YOKOGAWA 765501
277 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #180 background imageLoading...
Page #180 background image
16-8
IM 765501-01E
Command Function Page
:SPACing? Queries the sweep mode (linear or log) of the current sweep. 16-21
:STARt <Current>|MINimum|MAXimum
Sets the start value of the current sweep. 16-21
:STARt? [MINimum|MAXimum]Queries the start value of the current sweep. 16-21
:STOP <Current>|MINimum|MAXimum
Sets the stop value of the current sweep. 16-22
:STOP? [MINimum|MAXimum] Queries the stop value of the current sweep. 16-22
:STEP <Current>|MINimum|MAXimum
Sets the step value of the current sweep (linear sweep). 16-22
:STEP? [MINimum|MAXimum] Queries the step value of the current sweep (linear sweep). 16-22
:POINts <Integer>|MINimum|MAXimum
Sets the step count of the current sweep (log sweep). 16-22
:POINts? [MINimum|MAXimum]
Queries the step count of the current sweep (log sweep). 16-22
:ZERO
:IMPedance HIGH|LOW Sets the zero source impedance (high or low) for generating current. 16-22
:IMPedance? Queries the zero source impedance (high or low) for generating current. 16-22
:OFFset <Current> Sets the zero source offset value for generating current. 16-22
:OFFset? Queries the zero source offset value for generating current. 16-22
Sweep Commands (SWEep Group)
:SWEep
:TRIGger Starts the sweep operation. 16-23
:COUNt <Integer>|INFinity|MINimum|MAXimum
Sets the sweep repeat count. 16-23
:COUNt? [MINimum|MAXimum] Queries the sweep repeat count. 16-23
:LAST KEEP|RETurn Sets the sweep termination mode (keep level or return to initial level). 16-23
:LAST? Queries the sweep termination mode (keep level or return to initial level). 16-23
Measurement Commands (SENSe Group)
:SENSe
[:STATe] 1|0|ON|OFF Sets the measurement state (ON or OFF). 16-24
[:STATe]? Queries the measurement state (ON or OFF). 16-24
:FUNCtion VOLTage|CURRent|RESistance
Sets the measurement function (voltage, current, or resistance). 16-24
:FUNCtion? Queries the measurement function (voltage, current, or resistance). 16-24
:RANGe
:AUTO 1|0|ON|OFF Sets the measurement auto range (ON or OFF). 16-24
:AUTO? Queries the measurement auto range (ON or OFF). 16-24
:ITIMe <Time>|PLC|MINimum|MAXimum|UP|DOWN
Sets the integration time. 16-24
:ITIMe? [PLC|MINimum|MAXimum] Queries the integration time. 16-24
:DELay <Time>|MINimum|MAXimum
Sets the measurement delay. 16-24
:DELay? [MINimum|MAXimum] Queries the measurement delay. 16-24
:AZERo
[:STATe] 1|0|ON|OFF Sets the auto zero state (ON or OFF). 16-25
[:STATe]? Queries the auto zero state (ON or OFF). 16-25
:EXECute Executes auto zero. 16-25
:AVERage
[:STATe] 1|0|ON|OFF Sets the average state (ON or OFF). 16-25
[:STATe]? Queries the average state (ON or OFF). 16-25
:MODE BLOCk|MOVing Sets the average mode (block or moving average). 16-25
:MODE? Queries the average mode (block or moving average). 16-25
:COUNt <Integer>|MINimum|MAXimum
Sets the average count. 16-25
16.2 Commands

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA 765501 and is the answer not in the manual?

YOKOGAWA 765501 Specifications

General IconGeneral
BrandYOKOGAWA
Model765501
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals