16-12
IM 765501-01E
Command Function Page
:PARity? Queries the RS-232 parity (none, even, or odd). 16-36
:SBITs 1|2 Sets the RS-232 stop bit (1 bit or 2 bits). 16-36
:SBITs? Queries the RS-232 stop bit (1 bit or 2 bits). 16-36
:PACE NONE|XON|HARDware Sets the RS-232 flow control (none, XON-OFF, or CTS-RTS). 16-36
:PACE? Queries the RS-232 flow control (none, XON-OFF, or CTS-RTS). 16-36
:TERMinator CR|LF|CRLF Sets the RS-232 terminator (CR, LF, or CR+LF). 16-36
:TERMinator? Queries the RS-232 terminator (CR, LF, or CR+LF). 16-36
:ETHer
:MAC? Queries the MAC address of Ethernet communication. 16-37
:PORT? Queries the command socket port number of Ethernet communication. 16-37
:DHCP 1|0|ON|OFF Sets DHCP (ON or OFF) of Ethernet communication. 16-37
:DHCP? Queries the DHCP state (ON or OFF) of Ethernet communication. 16-37
:IP <String> Sets the IP address of Ethernet communication. 16-37
:IP? Queries the IP address of Ethernet communication. 16-37
:MASK <String> Sets the net mask of Ethernet communication. 16-37
:MASK? Queries the net mask of Ethernet communication. 16-37
:GATE <String> Sets the default gateway of Ethernet communication. 16-37
:GATE? Queries the default gateway of Ethernet communication. 16-37
:TERMinator CR|LF|CRLF Sets the terminator (CR, LF, or CR+LF) of Ethernet communication. 16-37
:TERMinator? Queries the terminator (CR, LF, or CR+LF) of Ethernet communication. 16-37
Measured Value Read Commands (INITiate, FETCh, and READ Group)
:INITiate Starts a new measurement. 16-38
:FETCh? Queries the measured results. 16-38
:READ? Starts a new measurement and queries the measured results. 16-38
Status Commands (STATus Group)
:STATus
:SOURce
:CONDition? Queries the source event condition register. 16-39
:EVENt? Queries the source event register and clears the register. 16-39
:ENABle <Integer>|<Binary/Octal/Hexadecimal>
Sets the source event enable register. 16-39
:ENABle? Queries the source event enable register. 16-39
:SENSe
:CONDition? Queries the measurement event condition register. 16-39
:EVENt? Queries the measurement event register and clears the register. 16-39
:ENABle <Integer>|<Binary/Octal/Hexadecimal>
Sets the measurement event enable register. 16-39
:ENABle? Queries the measurement event enable register. 16-39
Common Commands
*IDN? Queries the instrument model. 16-40
*OPT? Queries the options. 16-40
*TRG Generates a trigger. 16-40
*CAL? Performs calibration and queries the result. 16-40
*TST? Performs a self-test and queries the result. 16-40
*RST Initializes settings (resets to factory default settings). 16-40
*SAV 1|2|3|4 Saves the settings. 16-40
*RCL 1|2|3|4 Loads the saved settings. 16-40
*CLS Clears the event register and error queue. 16-40
*STB? Queries the status byte and clears the SRQ. 16-40
*SRE <Integer>|<Binary/Octal/Hexadecimal>
Sets the service request enable register. 16-40
*SRE? Queries the service request enable register. 16-40
*ESR? Queries the standard event register and clears the register. 16-40
16.2 Commands

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA 765501 and is the answer not in the manual?

YOKOGAWA 765501 Specifications

General IconGeneral
BrandYOKOGAWA
Model765501
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals