Scanner Profiles 6 - 7
Decoders
Use Decodes to configure individual decoder parameters.
UPCA
Report Check Digit - The check digit is the last character of the symbol used to verify the integrity of the
data. Enables or disables this option. A check in the checkbox indicates that the option is enabled (default -
True).
•Preamble- Preamble characters are part of the UPC symbol consisting of Country Code and System
Character. Select the appropriate option to match the host system.
There are three options for transmitting a UPCA preamble:
Preamble None - Transmit no preamble.
Preamble Sys Char - Transmit System Character only (default).
Preamble Country and Sys Char - Transmit System Character and Country Code (“0” for USA). Select
the appropriate option to match the host system.
UPCE0
Report Check Digit - The check digit is the last character of the symbol used to verify the integrity of the
data. Enables or disables this option. A check in the checkbox indicates that the option is enabled (default -
False).
•Preamble- Preamble characters are part of the UPC symbol consisting of Country Code and System
Character. Select the appropriate option to match the host system.
There are three options for transmitting a UPCE0 preamble:
Preamble None - Transmit no preamble (default).
Preamble Sys Char - Transmit System Character only.
Preamble Country and Sys Char - Transmit System Character and Country Code (“0” for USA).
Convert UPCE0 To UPCA - Enable to convert UPCE0 (zero suppressed) decoded data to UPC-A format
before transmission. After conversion, the data follows UPC-A format and is affected by UPC-A programming
selections. Disable to transmit UPCE0 decoded data as UPCE0 data, without conversion (default - False).
Code128
Length1 - Use to set decode lengths (default - 0). See Decode Lengths on page 6-13 for more information.
Length2- Use to set decode lengths (default - 55). See Decode Lengths on page 6-13 for more information.
Redundancy - Sets the reader to read the bar code twice before accepting data. A check in the checkbox
indicates that redundancy is enabled (default - False).
Enable Plain Code - Set the ISBT128 subtype. A check in the checkbox indicates that the option is enabled
(default - True).
ISBT128
Check ISBT Table - The If ISBT128 Concat Mode is set, enable this option to concatenate only those pairs
found in this table.m Other types of ISBT codes are not concatenated (default - False).