Dimensions (width x depth x height)
Axio Examiner.A1 with phototube and HAL 100 ......................................... 240 mm x 622 mm x 497 mm
Axio Examiner.Z1 with phototube and HAL 100 ......................................... 335 mm x 630 mm x 470 mm
Axio Examiner.A1 with phototube and HBO 100 ........................................ 240 mm x 653 mm x 497 mm
Axio Examiner.Z1 with phototube and HBO 100 ......................................... 335 mm x 661 mm x 470 mm
Axio Examiner.A1 with ergonomic phototube and HAL 100 ........................ 240 mm x 687 mm x 497 mm
Axio Examiner.Z1 with ergonomic phototube and HAL 100 ........................ 335 mm x 695 mm x 470 mm
Axio Examiner.A1 with ergonomic phototube and HBO 100 ....................... 240 mm x 718 mm x 497 mm
Axio Examiner.Z1 with ergonomic phototube and HBO 100 ........................ 335 mm x 726 mm x 470 mm
Weight
Axio Examiner.A1 .............................................................................................................. approx. 19 kg
Axio Examiner.D1 .............................................................................................................. approx. 21 kg
Axio Examiner.Z1 incl. control box .......................................... approx. 28 kg (control box: approx. 5.5 kg)
Environmental conditions
Transportation (in packaging):
Permissible ambient temperature ....................................................................................... -40 to +70 °C
Storage:
Permissible ambient temperature ...................................................................................... +10 to +40 °C
Maximum permissible atmospheric humidity (without condensation) ................................. 75 % at 35 °C
Operation
Permissible ambient temperature ...................................................................................... +10 to +40 °C
Maximum permissible relative humidity ............................................................................ 75 % at 35 °C
Maximum altitude for operation .................................................................................................. 2000 m
Barometric pressure .................................................................................................800 hPa to 1060 hPa
Pollution degree ................................................................................................................................... 2
Operational data
Field of application ....................................................................................................................... indoor
Safety class .............................................................................................................................................I
Degree of protection ....................................................................................................................... IP 20
Electrical safety ................................................................................. as per DIN EN 61010-1 (IEC 1010-1)
taking account of CSA and UL specifications
Overvoltage category ..............................................................................................................................
Radio and television interference suppression ....................................................... as per EN 55011 class B
Noise immunity ................................................................................................. as per DIN EN 61326/ A1
Power frequency................................................................................................................... 50 to 60 Hz