EasyManua.ls Logo

Zetor CRYSTAL Series - Hydraulic System; Hydraulic System Overview; Hydraulic Pump; Control Elements Placement

Zetor CRYSTAL Series
182 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Hydraulic syste
m
The system consists of the inner and outer circuit.
The source of pressurized oil is a gear pump.
Oil is drawn from the common filling of the gearbox and final drive housing.
Hydraulic pump
Control elements placement
Outer hydraulic circuit
The hydraulic pump cannot be disengaged. When the
engine is running, the pump is in operation.
The pressure generated in the hydraulic system by the
hydraulic pump is limited by a relief valve to 20 MPa.
Pump type Delivered quantity
GHD0 32/12,6L 85 l/min
F_02_113a
Control panel is placed on the right rear mudguard.
1. Electrohydraulics control
2. External hydraulic circuit control
C15N023
The outer circuit supplies pressurized oil to hydraulic
implements connected to the outer outlets of the hydraulic
system terminated with quick-couplers.
The sockets of the rear (A) as well as front (B) quick-
couplers have the inner diameter of 12.5 mm and comply
with the international ISO 5675 standard.
C15N024
HYDRAULIC SYSTEM
105

Table of Contents

Related product manuals