ZXR102900SeriesUserManual
4.Themeaningofthecontentandthestructureofaberengi-
neeringlabelareasshowninFigure26.
FIGURE26PATTERNANDMEANINGSOFTHEENGINEERING
LABELONTHEOPTICALFIBER
Thetwosidesoftheengineeringlabelontheopticalberare
marked“L”and“R”withthespecicmeaningsasfollows:
�WhenthelabelispastedontheberattheZXR10
2920/2928/2952/2936-FIside,therownumberandcolumn
numberofthecabinetatthesideoftheconnectedremote
opticalinterfacedeviceaswellasthelayerNo.oftheberin
thecabinetandtheberNo.shouldbelledintheRareaof
thelabel.Inthiscase,therowNo.andcolumnNo.ofZXR10
2920/2928/2952/2936-FIwheretheberislocatedaswellas
thelayerNo.oftheberandbernumbershallbelledin
theLareaofthelabel.
�Ifthelabelisattachedontheopticalinterfaceequipmentof
thecustomer ,contentslledonthelabelarejustcontraryto
thoseattheZXR102920/2928/2952/2936-FIside.
CableLightningProtection
Requirements
Accordingtothedegreeofhazard,lightningisclassiedintodi-
rectlightningstrikeandlightninginduction.Thedamageofdirect
lightningstrikeishardtoavoid.Butproperlightningprotection
measurecaneffectivelypreventthelightninginduction.Thefol-
lowinglightningprotectionrequirementsareproposedtoreduce
theequipmentfailurerateintheareaswherelightningisfrequent.
1.TheEthernetswitchshallbeplacedinthecorridor ,preferably
ontherstoor .Toavoidthedirectsunshine,rains,and
lightning,theswitchcannotstayinanoutdoorplacewhere
noweather-proofmeasuresaretaken.Ensurethatallsub-
scriberlines,excepttheuplink,downlink,andcascadinglines,
aredistributedinsidethebuildingtoavoidtheattackoflight-
ninginduction.