Chapter4ServiceConguration
commandlog:on
commandlogtimerstatus:enable
commandlogtimerinterval:10
adminSunJul405:56:442004showdate-time
adminSunJul405:55:382004showtime-range
adminSunJul405:54:162004showcommandloguseradmin
adminSunJul405:54:112004showuser
adminSunJul405:51:572004commandlogtimerinterval10
4.1.83showenvironment
Purpose
Thiscommandshowsenvironmentalvariables.
CommandMode
Globalcongurationmode
Syntax
showenvironment
Example
Thefollowingexampleshowsenvironmentalvariables:
zte(cfg)#showenvironment
SwitchSystemInfo:
CURRENTPOWER:8.8Watt
ENVI-NAMECURRENT-STATUSTHRESHOLD-HITHRESHOLD-LOW
--------------------------------------------------------------
TEMPERATURE0.0(C)51.0(C)49.0(C)
CPU-RATIO37.6%80.0%65.0%
MEM-RATIO67.2%80.0%75.0%
4.1.84showpower-module
Purpose
Thiscommandshowspowersupplymoduleinformation,includingAC,DC,outputvoltage,
outputcurrent,outputpower,inputpower,electronictag,temperatureofpowersupply
module,andmanufacturerinformation.