Chapter4ServiceConguration
CommandMode
Globalcongurationmode
Syntax
setethernet-oamport<portlist>link-monitorframe-periodthreshold<1-65535>window
<1-600000>
ParameterDescription
ParameterDescription
<portlist>Portlist.
<1-65535>Numberofincorrectframesinaunitperiod.
<1-600000>Numberofframescollectedinaunitperiod.
Guidelines
Theframeperiodisdeterminedbythenumberoftheframescollectedwithinaspecied
timeperiod.Thatis,whenthespeciednumberofframesarecollected,aperiodis
nished.Alinkalarmeventoccursifthenumberofthecollectedincorrectframesexceeds
thethresholdvalueruledbytheperiod.
Default
Thenumberofincorrectframesis1.
Thenumberofframescollectedinaunitperiodis100.
Example
Thefollowingexamplesetsthenumberofincorrectframesto2andthenumberofframes
collectedinaunitperiodto100:
zte(cfg)#setethernet-oamport1link-monitorframe-periodthreshold2
window100
4.30.11setethernet-oamportlink-monitorframe-seconds
Purpose
Thiscommandsetstheincorrectframecumulativeevent.
CommandMode
Globalcongurationmode
4-493
SJ-20130731155059-003|2013-11-27(R1.0)ZTEProprietaryandCondential