EasyManuals Logo

Zte ZXR10 2900E Series User Manual

Zte ZXR10 2900E Series
750 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #699 background imageLoading...
Page #699 background image
Chapter5ManagementConguration
CommandMode
SNMPcongurationmode
Syntax
setuser<string><string>v3[md5-auth<string>|sha-auth<string>[des56-priv<string>]]
ParameterDescription
ParameterDescription
user<string>Username
<string>Groupname
md5-auth<string>md5authenticationmodeandpassword
sha-auth<string>shaauthenticationmodeandpassword
des56-priv<string>des56encryptionpassword
Example
Thefollowingexamplesetstheusernametozte,groupnametoBN,authenticationmode
tomd5–auth,andpasswordtoabcforSNMPV3:
zte(cfg-snmp)#setuserzteBNv3md5-authabc
5.4.15settrapmacnotificationenable/disable
Purpose
ThiscommandenablesordisablesthefunctionofsendingatrapnoticationiftheMAC
addressischangedonthespeciedportortrunk.
CommandMode
SNMPcongurationmode
Syntax
settrapmacnotification{port<1-52>|trunk<1-15>}{enable|disable}
ParameterDescription
ParameterDescription
portSpeciedport.
<1-52>
Portnumber.Differentdeviceshavedifferentportnumberranges.
Inthesyntax,the2952Edeviceisusedasanexample.
trunkSpeciedtrunk.
5-19
SJ-20130731155059-003|2013-11-27(R1.0)ZTEProprietaryandCondential

Table of Contents

Other manuals for Zte ZXR10 2900E Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zte ZXR10 2900E Series and is the answer not in the manual?

Zte ZXR10 2900E Series Specifications

General IconGeneral
SeriesZXR10 2900E
CategorySwitch
Operating Temperature0°C to 45°C
Storage Temperature-40°C to 70°C
Ports10/100/1000Base-T
Uplink PortsSFP
Power SupplyAC or DC
Layer SupportLayer 2
Operating Humidity10% to 90% non-condensing
Storage Humidity5% to 95% non-condensing
Jumbo Frame9K
VLAN SupportYes

Related product manuals