28 ©2013 2GIG Technologies Inc. All Rights Reserved.
INSTALLER PROGRAMMING
ACCOUNT REGISTRATION
Theaccountregistrationdatawascreatedfromthe
installationcontractandisstoredina databaseat
theCentralStation.Thedataincludesitemssuchas
thecustomername,address,andtheCentral
StationtelephonenumberandassignedControl
Panelaccountnumber.
Theregistrationprocessisusedtoenrollthe
ControlPanelwi
ththeCen
tralStationandinvolves
thefollowing:
•Selectingthesensornum
berforaparticular
deviceSelectingtheRFsensortype
•Learning‐intheRFsensor’
sserialnumber
•Selectingtheotheroptionsforthese
nsoras
showninthefollowingdiagram
IMPORTANT: RFsensorsarereportedtothe
ControlPanelassensors#1‐48.
Q-1 Sub-Questions
TheoptionsthatcanbesetforeachRFsensorare:
•Sensornumber—
01‐48
•SensorType—
Exit/Entry,perimeter,interior...
•SensorEquipmen
tType—Certainsensortypes
willaskforequipmenttype
•SensorEquipment
Code—Sensormodel
(door/window,PIR,smokedetector,etc.)
•SensorOtherEquipmen
tCode—Enterspecial
equipmentcode(onlyshownforsensorssetas
“other”)
•SensorSerial#—Se
rialnumber
labeledon
sensor;manuallyenteror“learn”bysending
signal
•SensorE
quipment
Age—Newinstallor
existingsensor
•SensorLoopNum
ber—Built‐incontactsor
externalcontactsonDW11Door/Window
sensor
•SensorDi
alerDela
y—Delayedorinstant
communicatorreportsforthesensor(delay
timeissetbydialerabortwindow)
•SensorVo
ic
eDescriptor—Nameassignedto
thesensorandannouncedifprogrammed
•SensorRepo
rts—Communicatorreportsorno
communicatorreportsforthesensor
•SensorSuper
vise
d—ControlPanelchecksfor
statusreportsfromthesensor,ordoesnot
checkforstatusreports
•SensorChi
me—
Selectvoiceannouncement
andchimeoptionsforthesensor
1 Scrollbetweenoponsusingthe←and→
arrows.Movetothepreviousornextprompt
bypressingthe↑and↓arrows.
2 Toprogramanothersensorclicknext.
3 Toexitprogramming,clickskipthenendand
exit. Uponexit,the paneltakesaseveral
secondstoreboot.