Control Panel Programming Questions
©2013 2GIG Technologies Inc. All Rights Reserved.
49
Q-45 Select lock default
programming (0-2)
DEFAULT: Default all (0)
TheControlPanelmaybeabletobehardreset(or
softresetfromtheInstallerToolbox)toitsfactory
defaultvaluesdependingonthevalueenteredfor
thisprogrammingquestion.
TheControlPanelishardresetbypressingand
holdingtheandbuttonswhileapplying
powertotheControlPanel.
Thedef
aultlockoutfe
atureisprovidedtoprevent
takeovers.Threeoptionsareavailable:allow
defaultofalloptions,allowdefaultofsomebutnot
alloptions,notallowdefaultofanyoptions.
•Thedef
aultset
tingofdefaultall(0)allows
resettingtheControlPaneltoallitsfactory
defaults.
•Toallowres
et
tingtheControlPaneltoallits
factorydefaultsexcepttheCentralStation
phonenumber,CentralStationaccount
number,lockinstallerprogramming,download
ID,anddefaultlockoutfields,select(1).
•Toden
yhardand
softresettingoftheControl
Panel,selectdefaultnone(2).
Ifoption1or2isselecte
d,theoptiontakeseff ect
afterthesystemrunsfor48hours.Thisallowsthe
installertogobackandmakechangesifrequired.
Q-46 Select trouble doesn’t sound
at night (0-1)
DEFAULT: Enabled (1)
TheControlPanelwillsoundtroublebeepscaused
byACloss,systemlowbat t ery,sensorlowbattery
orRFsupervision,failuretocommunicate,Control
Paneltamperwhiledisarmed,andcellradiofaults.
Topreventannoyingthesubscriber,thesystemcan
besettosuppresstroublebeepsfromsounding
from10pmto9am.Thetr
oublealerts
arestill
displayedandimmediatelyreportedtotheCentral
Station,andcanbeacknowledged,buttheywon’t
soundbeepsuntilafter9am.
Ifthetroublecondition(s)self‐clearorare
acknowledgedbefore9am,notroublebeepssound
after9am(theconditionsarestillrecordedinthe
eventlog).
•Thedef
ault(1)suppre
ssestroublebeepsfrom
10pmto9am
•Toallowtr
oublebeepsatan
ytime,select
disabled(0)
WARNING: ForUL985Installations,this
featureMUSTBEdisabled.
Q-47 Select trouble resound after
hold off (0-7)
DEFAULT: Disabled (0)
FireandCOsensorsarerequiredtore‐sound
troublebeepseveryfourhoursuntilthetroubleis
resolved,evenifthetroubleisacknowledgedatthe
ControlPanel.TheControlPanelcanbesettodelay
re‐soundingthesetypesoftroublebeepsfor1‐7
days.
NOTE: ThisfeatureisnotallowedinUL985
installations.Thesettingmustbedisabled
(0)inthisgradeofinstallation.
•Thede
fault(0)allowstroub
lebeepsforCO
andfiresensorstore‐soundeveryfourhours
afterbeingacknowledged
•Todelayre‐soundingtr
oublebeepsforCOand
firesensors,select(1‐7)days
Q-48 Enter download CSID (6 digits)
DEFAULT:000000
Thesystemsupportsa6‐digitCSIDcodethatis
usedforremotetelephoneprogrammingofthe
ControlPanel.Thiscodeisverifiedwhenthe
ControlPanelconnectswiththedownloading
software.IftheCSIDcodedoesn’tmatchthe
downloadingsoftware,theControlPanelwilldeny
theconnection.
•TheCSIDcodecanbe en
ter
edmanuallywith
thisprogrammingquestion.
•Ifthisfieldislef
twiththedefault(000000),
thefirsttimethedownloadingsoftware
connectswiththeControlPanel,thefieldwill
befilledwiththesoftware’sCSID.
Q-49 Select programming mode
entry reports to CS (0-1)
DEFAULT: Disabled (0)
AreportcanbesenttotheCentralStationanytime
installerprogrammingmodeisenteredandexited.
•Thedefault(0)prev
entsreporting
programmingmodeentryandexit.
•Toreportprogr
ammingmodeentryandexit,
selectenabled(1).
NOTE: Thisreportcanonlybesentthrough
thetelephonedialer.Itisnotsupported
throughthecellradiomodule.