Control Panel Programming Questions
©2013 2GIG Technologies Inc. All Rights Reserved.
47
NOTE: Thedialerdelaycanbedisabledper
sensorwithoutaffectingSIACP‐01
compliance.See"RFSe
nsorProgr
amming
Steps"onpage30.
Q-36 Select burglary bell cutoff
(0-4)
DEFAULT: 4 minutes (0)
Whenaburglaryalarmistriggered,thebellwill
sounduntiltheburglarybellcutofftimeexpires.
•Thedefault(0)set
stheburglarybellcutoffto
4minutes.
•Tochangetheburglar
ybellcutofftime,select
(1),(2),(3),or(4).
(0)4minutes
(1)8minutes
(2)12minutes
(3)16minutes
(4)Unlimitedtime
NOTE: The24‐hourAuxiliaryAlarmZone(08)
doesnotfollowtheburglarybellcutoff
timeandwillsoundtheControlPanel’ s
localalarmuntilaUserCodeisentered.
TheAuxiliaryAlarmZonedoesnottrigger
theexternalsiren(ifused).
Q-37 Select fire bell cutoff (0-4)
DEFAULT: 4 minutes (0)
Whenafirealarmistriggered,thebellsoundsuntil
thefirebellcutofftimeexpires.
•Thedefault(0)set
sthefirebellcutofftimeto
4minutes.
•Tochang
ethefir
ebellcutofftime,select(1),
(2),(3),or(4)
(0)4minutes
(1)8minutes
(2)12minutes
(3)16minutes
(4)Unlimitedtime
Q-38 Enter time to detect AC loss, in
minutes (0-30)
DEFAULT: 10 minutes (10)
ACpowerlosswillcauseanACpowerlossalert
tobedisplayed,andthelengthoftimebefore
itisdisplayedcanbeset.Whenpowerreturns,the
timerequiredbeforetheACpowerlossalert
automaticallyclearsisfix edatoneminute.
•Thede
fault(10)set
stheACpowerlossalert
displaytimetotenminutes.
•Tochang
etheACpow
erlossalertdisplay
time,enter(0‐30)minutes.
NOTE: AftertheACpoweralert is
displayedorclear
s,theACpowerloss
reportorACpowerrestorereportcanbe
senttotheCentralStationimmediately,or
atarandomtime,seeQ‐39.
NOTE: TheControlPanel’ sACpowericon
displaysthepowerstatusimmediately.A
red“X”overtheiconindicatesnoAC
power.
Q-39 Select random AC loss report
time (0-1)
DEFAULT: Enabled (1)
ThisfeatureallowsthesystemtoreportACpower
lossandACpowerrestoreatarandomtimeofup
to45minutesaftertheeventoccurs.Thishelpsto
reduceCentralStationcongestionduetoawide‐
spreadpoweroutageaff ectingmanyControlPanels
atonce.TherandomACpowerst
atusreporttimer
istrigger
edbasedonthetimesetbyQ‐38.
•Thedefault(1)allowsr
andomtimedACpower
reports.
•Toturnoffra
ndomtimedACpowerreports,
selectdisabled(0).
Q-40 Enter CS #2 phone number (0-
25 digits)
DEFAULT: No default
ThetelephonenumberforCentralStation#2can
beupto25digits.CentralStationtelephone#2is
dialedasbackupincasetelephone#1doesnot
connect.
•EntertheCe
nt
ralStation#2telephone
number.
•TheSh
iftbu
ttonaccessesthepoundandstar
symbols.ThePbuttonaddsa3‐secondpause
tothedialing.
Q-41 Enter CS #2 account number
(4 digits)
DEFAULT: No default
TheaccountnumberforCentralStation#2is
alwaysfourdigitsandcanincludesomealpha
characters.
BurglaryBellCutoffTime
FireBellCutoffTime