Q-64 Select smart test reports
DEFAULT: Disabled (0)
SmarttestreportsareawaytoreduceCentral
Stationtraffic.Ifsmarttestreportsareenabledand
regularperiodictestreportsareenabled,anynon‐
testreporttotheCentralStation(alarm,restore,
trouble,etc.)duringthenormaloperationofthe
systemwillresettheperiodictestreporttimer.
Periodictestre
portswou
ldonlybesentifthe
ControlPanelhasnotreportedinanywaytothe
CentralStation.
•Thedef
ault(0)prev
entssmarttestreports.
•Toallowsmarttestrepo
rts,selectenabled(1).
Q-65 Select RF jam causes trouble
(0-1)
DEFAULT: Disabled (0)
ThesystemcanmonitortheControlPanel’ssensor
receiveranddetectwhetheratransmitterisstuck
ontheaircausingjamming.Whenjamdetectis
enabled,theControlPanelwillindicateatrouble
conditionifRFjammingisdetected.
NOTE: Thisprogrammingquestiononly
functionsiftroublereportsareenabled
withprogrammingquestionQ‐50.
•Thedef
ault(0)disablesRFja
mdetection.
•ToturnonRFjamdetection,selectena
bled
(1).
Q-66 Select daylight saving (0-1)
DEFAULT: Enabled (1)
TheControlPanelcanadjustitsdisplayedclockand
internalclockfordaylightsavingtime.Ifthecell
radioisused,thetimewillbeautomatically
adjustedregardlessofthissetting.Thesystem
defaultissetforpost2007daylightsaving
changeoverdates.Thesedatescanbemodifiedin
casetheda
ylightsavingchang
eoverdat emoves
again.
•Thedefault(1)enab
lesdaylightsavingtime
adjustment.
•Toturnoffauto
maticdaylightsavingsadjust,
selectdisabled(0).
NOTE: Ifrequired,useprogrammingquestions
Q‐67,Q‐68,Q‐69,andQ‐70tomodifythe
daylightsavingstartandstopdates.
Q-67 Select daylight saving start
month (01-12)
DEFAULT: March (03)
•Thedefault(03)setsMarchasthedaylight
savingstartmonth.
•Tochang
ethesta
rtmonth,enterthemonth,
January‐December(01‐12),thatthenew
daylightsavingtimewillstart.
Q-68 Select daylight saving start
Sunday (1-7)
DEFAULT: 2nd Sunday (2)
•Thedefault(2)setsthesecondSundayasthe
daylightsavingstartweek.
•Tochangethesta
rtweek,enterthe1st,2nd,
3rd,4th,last,secondfromlast,thirdfromlas t
(1‐7)asthedaylightsavingstartweek.
Q-69 Select daylight saving end
month (01-12)
DEFAULT: November (11)
•Thedefault(11)setsNovemberasthedaylight
savingendmonth.
•Tochangetheendmon
th,enterthemonth,
January‐December(01‐12),thatthecustom
daylightsavingtimewillend.
Q-70 Select daylight saving end
Sunday (1-7)
DEFAULT: 1st Sunday (1)
•Thedefault(1)setsthefirstSundayasthe
daylightsavingendweek.
•Tochangetheendweek,
enterthe1st,2nd,
3rd,4th,last,secondfromlast,thirdfromlas t
(1‐7)asthedaylightsavingendweek.
Q-71 Select system tamper causes
trouble (0-1)
DEFAULT: Enabled (1)
AtamperswitchontheControlPaneldetectsifthe
casehasbeenopened.Thesystemcanbe
programmedsothatatamperswitchactivationwill
causeatroubleindicationifthesystemisdisarmed,
andanalarmifthesystemisarmed.
•Thede
fault(1)allowstheCon
trolPanel
tamperswitchtotriggertroublewhenthe
systemisdisarmed,andalarmwhenthe
systemisarmed.