RF Sensor Programming Steps
©2013 2GIG Technologies Inc. All Rights Reserved.
33
Select RF sensor (#) chime (0-5)
DEFAULT: Disabled (0)
EachRFsensorcanbesettosounda“dingdong
chimeand/orsounditsvoicedescriptorwhenthe
sensoristriggered.Thisstepdeterminestheinitial
settingforthesensor.Theendusercanchangethe
chimesettingforsensorsusingChimeSetupinthe
UserToolbox.
•Thedef
ault(0)disablesthechimefo
rthisRF
sensor.
•Ifachimeand/
orvoi
ceisrequiredforthisRF
sensor,chooseoneofthe otherchime
options:
RFSensorChime
(0)disabled (7)dingdingwithvoice
(1)voiceonly
(8)dingdong#3
(2)dingdongwithvoice#1 (9)dingdongwithvoice#3
(3)dingdong#2
(10)chime#1
(4)dingdongwithvoice#2 (11)chime#1withvoice#1
(5)dingdong#1
(12)chime#2
(6)dingding (13)chime#2withvoice#2
WIRED SENSOR
PROGRAMMING
Wired Sensor Programming Outline
TheControlPanelcanbeprogrammedwithupto2
wiredsensors.Thewiredsensorsarehardwired
contactloopsconnectedtotheloopinput
terminalsontheControlPanel sterminalstrip.To
seewherethe2hardwiredsensorscanbewired
intotheTerminalBlock,seethe"TerminalBlock
WiringDiagram"onpa
ge15.
CAUTION:Wired Sensors CANNOT be used
for a CO or Fire Sensor Loop!
ToprogramthewiredsensorsintotheControl
Panel,dothefollowing:
•Selectthese
nsornu
mber(between1or2)
•Selectthewiredse
nsortype
•Settheequipmentco
de
•Programthelooptype:
•Op
en
•Closed
•Endofli
neresi
stor
•Selecttheotheroptionsforthese
nsor(see
thediagramonthenextpage)
IMPORTANT: Wiredsensors1and2reporttothe
ControlPanelassensors49and50.
Wired Sensor Reporting Codes
WiredSensor#1=ReportsasSensor#49
WiredSensor#2=ReportsasSensor#50
Seethediagramonthenextpageforthesteps
requiredtoprogramwiredsensorsintotheControl
Panel.Theoptionsthatcanbesetforeachwired
sensorare:
•WiredSensorNumberSensor#1or2
•WiredSensorTy
pe
Exit/entry,perimeter,
interior,etc.
•WiredSensorE
quipmen
tTypeCertain
sensortypeswillrequiretheinstallertoenter
anequipmenttype(butnotall)
•WiredSensorEquipmen
tCode4digit
equipmentcodethatmatchesinstalledsensor
•WiredSensorE
quipmentAgeNewinstallor
existingsensor
•WiredSensorNor
malSt
atenormallyopen,
closed,orendoflineresistorloop
•WiredSensorDialerDel
ayDelayedor
instantcommunicatorreportsforthesensor
(delaytimeissetbydialerabortwindow)
•WiredSensorVo
ic
eDescriptorName
assignedtothesensor
•WiredSensorRepo
rtsCommunicator
reportsornocommunicatorreportsforthe
sensor
•WiredSensorChime
Selectvoice
announcementandchimeoptionsforthe
sensor

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the 2gig Technologies Go Control and is the answer not in the manual?

2gig Technologies Go Control Specifications

General IconGeneral
Brand2gig Technologies
ModelGo Control
CategorySecurity System
LanguageEnglish

Related product manuals