32 ©2013 2GIG Technologies Inc. All Rights Reserved.
Go!Control Wireless Security System | Install Guide
Select RF sensor (#) loop number
(1-3)
DEFAULT: Varies with sensor model
selected
2GIGDW10door/windowsensorshavetwoinputs:
aninternalmagneticcontactandanexternal
normallyclosedhardwiredinput.Eitherorboth
sensorinputscanbeused.
TIP: Somesensorsarecap ableofthreeloop
inputs.
Whenusingboththein
te
rnalmagneticcontactand
theexternalinput,themagnetcontactandthe
externalcontactneedtobeassignedadifferent
RFsensornumber.Bothsensornumberswill
sharethesamesensorserialnumber.
•Whenpr
ogra
mmingthesensortousethe
builtinmagneticcontact,settheloopnumber
to(2).
•Whenprogra
mmingthesensortouseits
hardwiredinput,settheloopnumberas(1).
•Whenpr
ogra
mminga3loopsensortousean
additionalinput,settheloopnumberas(3).
•Whenente
ringthesensornumberforthe
sensorsloop2or3,thepastebuttoncanbe
usedtorecallthelastprogrammedsensors
serialnumber. (Thesensornumberwillbe
filledinautomaticallyifLearnisused.)
Select RF sensor (#) dialer delay
(0-1)
DEFAULT: Enabled (1)
(Required SIA CP-01 Default)
RFsensorscantriggerthecommunicator
immediatelyorafteradelay.Thedelaytimeisset
bytheabortwindowdialerdelayprogramming
questionQ35(thedefaultdelayis30seconds).
•Thedef
ault(1)cau
sesdelayeddialingforthis
RFsensornumber.
•Forimmedi
atedialingforthisRFsensor
number,selectdisabled(0).
NOTE: ThissettingforCOandsmokedetectors
isautomaticallysettodisabled(0),and
thissubquestionisskippedforthese
sensortypes.
NOTE: Thisdefaultcanbechangedwithout
aff ectingSIACP01compliance.
Construct RF sensor (#) voice
descriptor
DEFAULT: No default
ThevoicedescriptorsarethewordstheControl
Panelwi llannounceforthisRFsensorifthissensor
isprogrammedforvoiceannunciation.Uptofive
wordsareallowed.
1 Pressinserttoplaceawordfromthe
vocabularyintothedataentryfield.
2 Usethe←or→arrowstoscrollthroughthe
words,orentertheword’s3digitindex
number(see"SystemV
ocabularyTab
le"on
page27).
3 Pressinsertagainforthenextword.Uptofive
wordsareallowed.
4 Tomovebetweenwords,presstheFwdand
Backbuttons.
5 Toremoveaword,pressDelete.
Select RF sensor (#) reports (0-1)
DEFAULT: Enabled (1)
RFsensorscanbeprogrammedtotriggerareport
totheCentralStationornot.
•Thedefault(1)enab
lesreportingforthisRF
sensornumber.
•Topreventrep
ortingforthisRFsensor
number,selectdisabled(0).
Select RF sensor (#) supervised
(0-1)
DEFAULT: Enabled (1)
Whenasensorissettosupervised,theControl
Panelwillexpectregulartimedsignalsfromthis
sensororelseasensorsupervisorytroublealert
willoccur.
•Thede
fault(1)allowssuperv
isionforthisRF
sensor.
•Toturnoffsuperv
isionforthisRFsensor,
selectdisabled(0).
NOTE: Portablesensorssuchaspanicbuttons
shouldnotbesetassupervisedifthe
sensorwillberemovedfromthepremises
attimes.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the 2gig Technologies Go Control and is the answer not in the manual?

2gig Technologies Go Control Specifications

General IconGeneral
Brand2gig Technologies
ModelGo Control
CategorySecurity System
LanguageEnglish

Related product manuals