RF Keypad Programming Steps
©2013 2GIG Technologies Inc. All Rights Reserved.
41
Select RF Keypad (#) equipment
age (0-1)
DEFAULT: New (0)
TheControlPanelcanbeusedwithneworexisting
RFkeypads.
•IfthisRFKeyp
adisnewfortheinstallation,
leavethedefaultofnew(0).
•IfthisRFKeyp
adisalreadyinstalled,select
existing(1).
Select RF Keypad (#) emergency
keys (0-1)
DEFAULT: Enabled (1)
NOTE: ThisstepisnotdisplayedforModel
2GIG‐TS1keypads.
StandardRFke
yp
adshave24‐houremergency
buttonslabeledFireandPolice.
•Thedefault(1)enab
lesthisRFKeypad’ s
emergencykeys.
•TodisablethisRFKey
pad
’semergencykeys,
selectdisabled(0),thekeyswillnotbeableto
triggeranalarmorreport.
NOTE: TheRFKeypad’ sPOLICEbuttontriggers
asilentalarmifprogrammingquestionQ‐
16issettosilentpanic.
IMPORTANT: Toensurethatasignalissent,
instructtheendusertopresstheRFKeypad’ s
emergencykeysuntiltheKeypad’sindicator
lights.
Construct RF Keypad (#) voice
descriptor
DEFAULT: Keypad (#)
ThevoicedescriptoristhewordstheControlPanel
willannounceforthisRFKeypad.Uptofivewords
areallowed.
1 PressInserttoplaceawordfromthe
vocabularyintothedataentryfield.
2 Usethe←or→arrowstoscrollthroughthe
words,orenterthewor d’s3‐digitindex
number.
3 PressInsertagainforthenextword.Uptofive
wordsareallowed.
4 Toremoveaword,pressDelete.

Table of Contents