PROGRAMMING QUESTION TABLE
Q# Question Default
Q1
SelectRFsensor#(0148)
SelectRFsensor(#)type (00)unused
SelectRFsensor(#)equipmenttype VariesbyRFsensortype
(onlyshownforsome
sensortypes)
SelectRFsensor(#)equipmentcode (0000)other
EnterRFsensor(#)otherequipmentcode
(09999)
0Onlyshownifotheris
selected
EnterRFsensor(#)serialnumber(7digits) 0000000
SelectRFsensor(#)equipmentage(01) (0)new
SelectRFsensor(#)loopnumber(13) Varieswithsensormodel
selected
SelectRFsensor(#)dialerdelay(01) (1)enabledexceptforfire
andCO
ConstructRFsensor(#)voicedescriptor Nodefault
SelectRFsensor(#)reports(01) (1)enabled
SelectRFsensor(#)supervised(01) (1)enabled
SelectRFsensor(#chime(05) (0)disabled
Q2
Selectwiredsensor#(12)
Selectwiredsensor(#)type (00)unused
Selectwiredsensor(#)equipmenttype Variesbywiredsensortype
(onlyshownforsome
sensortypes)
Enterwiredsensor(#)equipmentcode(09999) 0
Selectwiredsensor(#)equipmentage(01) (0)new
Selectwiredsensor(#)normalstate (0)notused
Selectwiredsensor(#)dialerdelay (1)enabled
Constructwiredsensor(#)voicedescriptor(01) Nodefault
Selectwiredsensor(#)reports(01) (1)enabled
Selectwiredsensor(#)chime(05) (0)disabled
Q3
Selectfob#(18)
Selectfob(#)used(01) (0)unused
Selectfob(#)equipmentcode(0000) (0000)other
Enterfob(#)otherequipmentcode
(09999)
0Onlyshownifotheris
selected
Enterfob(#)serialnumber(7digits) 0000000
Selectfob(#)equipmentage(01) (0)new
Selectfob(#)emergencykey(04) (0)disabled
Selectfob(#)key2candisarm(01) (1)enabled
Constructfob(#)voicedescriptor keyfob#
Selectfob(#)armnodelay(01) (0)disabled
Selectfob(#)key4output(02) (0)disabled
Q4
SelectRFkeypad#(14)
SelectRFkeypad(#)used(01) (0)unused
SelectRFkeypad(#)equipmentcode (0000)other
EnterRFkeypad(#)otherequipmentcode
(09999)
0Onlyshownifotheris
selected
EnterRFkeypad(#)serialnumber(7digits) 0000000
SelectRFkeypad(#)emergencyage(01) (0)new
SelectRFkeypad(#)emergencykeys(01) (1)enabled
ConstructRFkeypad(#)voicedescriptor keypad#
Q5 Enterexitdelay,inseconds(45120) 60seconds
Q6 Enterentrydelay1,inseconds(30240) 30seconds
Q7 Enterentrydelay2,inseconds(30240) 45seconds
Q8 Selectdialer(01) (0)disabled
Q9 Enterdialingprefix(04digits) Nodefault
Q10 Entercallwaingdisablecode(06digits) Nodefault
Q11 EnterCS#1phonenumber(025digits) Nodefault
Q12 EnterCS#1accountnumber(4digits) Nodefault
Q13 Select2wayvoice(02) (1)stayonline
Q14 Selectsilentpanic/burglarylistenonly(01) (1)enabled
Q15 Selectdialingtype(01) (0)touchtone
Q16 Selectpoliceemergencykey(02) (1)audible
Q17 Selectfireemergency(01) (1)audible
Q18 Selectemergencykey(01) (1)audible
Q19 Selectquickarming(01) (1)enabled
Q20 Selectswingershutdowncount(16) (2)twotrips
Q21 Selectsirensupervisiontime(03) (0)disabled
Q22 EnterCSlackofusagenotificationtime0255 7 Days
Q23 Enterradiomodemnetworkfailuretime0255 30minutes
Q24 Selectradionetworkfailurecausestrouble01 (1)enabled
Q25 Selectradiomodemnetworkfailurereports01 (1)enabled
Q26 Selectautostay(01) (1)enabled
Q27 Selectexitdelayrestart(01) (1)enabled
Q28 Selectquickexit(01) (1)enabled
Q29 Enterperiodictest,indays(0255) 30days
Q31 Entercancelme,inminutes(5255) 5minutes
Q32 Selectcanceldisplay(01) (1)enabled
Q33 Selectcrosssensor4748(01) (0)disabled
Q34 Entercrosssensortimeoutinseconds(10120) 10seconds
Q35 Selectabortwindowdialerdelay(02) (1)30seconds
Q36 Selectburglarybellcutoff(04) (0)4minutes
Q37 Selectfirebellcutoff(04) (0)4minutes
Q38 EntertimetodetectAClossreporttime(030) 0minutes
Q39 SelectrandomAClossreporttime(01) (1)enabled
Q40 EnterCS#2phonenumber(025digits) Nodefault
Q41 EnterCS#2accountnumber(4digits) Nodefault
Q42 Selectremotecontrolphone(03) (3)dataandvoice
Q43 Enterinstallercode(4digits) 1561
Q44 Selectlockinstallerprogramming(02) (0)disabled
Q45 Selectlockdefaultprogramming(02) (0)defaultall
Q46 SelecttroublereportstoCS(01)* (1)enabled
Q47 Selecttroubleresoundafterholdoff(07) (0)disabled
Q48 Enterdownloadcsid(6digits) 000000
Q49 SelectprogrammingmodeentryreportstoCS(01) (0)disabled
Q50 SelecttroublereportstoCS(01) (1)enabled
Q51 SelectmanualbypassreportstoCS(01) (0)disabled
Q52 SelectAClossreportstoCS(01) (1)enabled
Q53 SelectsystemlowbatteryreportstoCS(01) (1)enabled
Q54 SelectRFlowbatteryreportstoCS(01) (1)enabled
Q55 SelectopeningreportstoCS(01) (0)disabled
Q56 SelectclosingreportstoCS(01) (0)disabled
Q57 SelectalarmrestorereportstoCS(01) (0)disabled
Q58 SelecttroublerestorereportstoCS(01) (1)enabled
Q59 SelectbypassrestorereportstoCS(01) (0)disabled
Q60 SelectACrestorereportstoCS(01) (1)enabled
Q61 SelectsystemlowbatterrestoresreporttoCS(01) (1)enabled
Q62 SelectRFlowbatteryrestoresreportstoCS(01) (1)enabled
Q63 Selectphonefaildetect(01) (0)disabled
Q64 Selectsmarttestreports(01) (0)disabled
Q65 SelectRFjamcausestrouble(01) (0)disabled
Q66 Selectdaylightsaving(01) (1)enabled
Q67 Selectdaylightsavingstartmonth(01‐12) (03)March
Q68 SelectdaylightsavingstartSunday(17) (1)2nd
Q69 Selectdaylightsavingendmonth(0112) (11)November
Q70 Selectdaylightsavingendsunday(17) (1)1st
Q71 Selectsystemtampercausestrouble(01) (1)enabled
Q72 Selectquickbypass(01) (0)disabled
Q73 Selectdisarmingkeyfobafteralarmalert(01) (0)disabled
Q74 Selectkeyfobarm/disarmconfirmation(01) (0)disabled
Q75 Selectautounbypassformanualbypass(01) (1)enabled
Q76 Selectforcebypassreports(01) (0)disabled
Q77 Selecteventlog(03) (3)allevents
Q78 Selectoutput(0010) 11followsinternal
sounderalarm
Q79 SelectZWavefeature(03) (1)disabledbyvisible
Q80 SelectZWaveswitchesfeature(01) (0)disabled
Q81 SelectZWavethermostatsfeature(01) (0)disabled
Q82 SelectZWaveswitchesfeature(01) (0)disabled
Q83 Selecttemperaturedisplayunits(01) (0)degreesFahrenheit
Q84 Selectservicesrequiremastercode (0)disabled
Q85 Selectmasteruseraccesstoz (0)disabled
Q86 Selectdisablesirenaftertwowayaudio(01) (0)disabled
Q87 Selectkeyfob/remotearmingmodeonsystemnot
ready(02)
(0)autobypasswithzone
participationonrestore
Q88 Selectsirenmode(01) (0)soundforburglaryand
Fire/CO
Q89 Selectallowbacklightalwayson(demomode) (0)disabled
Q90 Selectenergyfeature (1)enabled
Q91 Selectradiomodemsupplier (02)dependsonsupplier
DefaultsetforSIACP01compliance
*ForUL985Installations,thisfeaturemustbedisabled

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the 2gig Technologies Go Control and is the answer not in the manual?

2gig Technologies Go Control Specifications

General IconGeneral
Brand2gig Technologies
ModelGo Control
CategorySecurity System
LanguageEnglish

Related product manuals