RF Sensor Programming Steps
©2013 2GIG Technologies Inc. All Rights Reserved.
31
Enter RF sensor (#) serial number
(0-9999)
DEFAULT: 0
NOTE: Thisquestionisonlydisplayedif
“(0000)otherisselectedforasensors
equipmentcode.
Theequipmen
tcodeisa4digitcodethatis
a
ssignedtothemodelofsensorbeingused.Ifnew
equipmentbecomesavailable,thenewequipment
codeshouldbeenteredhereifthenewequipment
isnotlistedintheSensorEquipmentCodestable
above.
•Entertheequipm
entcodenumber
directlyon
thekeypadfortheRFsensor.(Enter“0”ifthe
newequipmentcodeisunknown.)
Enter RF sensor (#) serial number
(7 digits)
DEFAULT: 0000000
RFsensorserialnumberscanbemanuallyentered
orlearnedfromthesensor.
•Formanualentry,en
terthesensornumber
thatwasloggedforthesensorbeing
programmed.UsetheShiftbuttontoaccess
alphacharacters.
•Forautom
aticen
try,pressShift,thenpress
Learn.TheControlPanelwillwaitforasensor
transmission.Triggerthesensorbeing
programmedandtheControlPanelwillbeep
fourtimesandlearnthesensorsserial
number.
Ifthesensorbeingle
arne
disalreadyinmemory,
theControlPanelwilldisplayasensorlearning
failurescreenwhentheprogrammingchangesare
beingsaved.
Forcertainsensorswithmorethantwoloops,the
tamperswitchmustbeusedtosendasignaltothe
ControlPanelduringsensorlearning.Firstpr
essof
tamp
erswitchwilllearnasLoop#1,thesecond
pressoftamperswitchwilllearnasLoop#2,the
thirdpressoftamperswitchwilllearnasLoop#3.
Wait15secondsbetweeneachpressofthe
tamperswitch.
Theprogrammedloopnumberofthesensorinthe
ControlPanelma
yneedchangingtosuitthe
oper
ationofthedevice.SeetheInstallInstructions
ofthesensorfordetails.
Select RF sensor (#) equipment age
(0-1)
DEFAULT: New (0)
TheControlPanelcanbeusedwithneworexisting
RFsensors.
•IfthisRFsensorisnewfortheinst
allation,
leavethedefaultofnew(0).
•IfthisRFsensorisalrea
dyinstalled,select
existing(1).
NOTE: IftheRFsensorhasmorethanoneloop
andisbeingprogrammedintomultiple
sensornumberstosupporttheloops,set
onlyoneloopas“newandtheother
loopsas“existing .Thiswillprevent
incorrectinventoryoftheinstalled
sensors.
Sensor Equipment Codes
(0000)other
(0862)DW10345ThinDoor/WindowContact
(0863)DW20R345RecessedDoorContact
(0869)PIR1345PIRwithPetImmunity
(0864)GB1345Glassbreakdetector
(0895)SMTK2345GESmoke/Heatdetector(USA/Canada)
(1058)SMTK33452GIGSmokeDetector
(0872)SMKE1345SmokeDetector(USA)
(0871)SMKE1345CSmokeDetector(Canada)
(0868)PANIC1345PanicButtonRemote
(0860)CO1345CODetector(USA)
(0859)CO1345CODetector(Canada)
(1026)CO33452GIGCODetector(USA/Canada)
(0873)TAKE345TakeoverModule
(0637)HWD/W”5816”
(0470)HWRD/W“5818MNL
(0533)HWPIR“5890”
(0530)HWPIR“5894Pi
(0519)HWGlassBreak“5853”
(0589)HWSmoke“5808W3
(0557)HWHeatSensor“5809”
(0624)HWFloodSensor“5821”
(0491)HWPanicPendant“5802MN2”
(0655)ExistingDoor/WindowContact
(0609)ExistingMotionDetector
(0475)ExistingGlassBreakDetector
(0616)ExistingSmokeDetector
(0692)ExistingCODetector
(0708)ExistingHeatSensor
(0556)ExistingFlood/ TempSensor
(1061)Garage01ResolutionProductsTiltSensor
(1063)DBELL13452GIGDoorbell

Table of Contents