44 ©2013 2GIG Technologies Inc. All Rights Reserved.
Go!Control Wireless Security System | Install Guide
Q-16 Select police emergency key
(0-2)
DEFAULT: Audible (1)
TheControlPanel’ spanicemergencybuttonaction
canbeprogrammed.Thepanicemergencybutton
isdisplayedbypressingthebutton.
•Thedefault(1)allowsthepa
nicemergency
buttontosoundanaudiblealarm.
•Forsi
lentactiva
tion,selectsilentpanic(2).
•Todisableandnotdisplaythepan
ic
emergencybutton,selectdisabled(0).
NOTE: Settingthisprogrammingquestionfor
silentpanic(2)makesthePolicebutton
onallRFkeypadssilentalso.
Q-17 Select fire emergency key
(0-1)
DEFAULT: Audible (1)
TheControlPanel’ sfireemergencybuttoncanbe
enabledordisabled.Thefireemergencybuttonis
displayedbypressingtheControlPanel’s
button.
•Thedef
ault(1)allowsthefir
eemergency
buttontosoundanaudiblealarm.
•Todisableandnotdispla
ythefireemer
gency
button,selectdisabled(0).
Q-18 Select emergency key (0-1)
DEFAULT: Audible (1)
TheControlPanel’ semergencybuttoncanbe
enabledordisabled.Thepanel’semergencybutton
isdisplayedbypressingtheControlPanel’ s
button.
•Thedef
ault(1)allowstheemer
gencybutton
tosoundanaudible alarm.
•Todisableandnotdispla
yemerg
encybutton,
selectdisabled(0).
NOTE: Ifallthreeemergencybuttonsare
disabled,pressingtheControlPanel’ s
buttondisplaysame
ssagethatthe
emergencybuttonsaredisabled.
Q-19 Select quick arming (0-1)
DEFAULT: Enabled (1)
Quickarmingallowsthesubscribertoarmthe
systemwithouthavingtoentertheirUserCode.
(QuickarmingreportsasUser0ifopen/close
reportsaresent.)
•Thedef
ault(1)allowsquickarming.
•T
oturnoffquickarming,selectdisable
d(0).
Q-20 Select swinger shutdown
count (1-6)
DEFAULT: Two trips (2) (Required SIA
CP-01 Default)
Anunwantedseriesofmultiplefaults(usually
causedbyabadcontactorsensor)iscalleda
“swinger. ”Swingershutdownsetsthemaximum
numberofalarmsthatanysensororhardwireloop
cantriggerduringasinglearmingperiod.
NOTE: COandsmokedetectoralarmsarenot
limitedbytheswingershutdowncount.
Othertypesof24‐hourzonesarelimited
bytheswingershutdowncount.
•Thede
fault(2)set
stheswingershutdown
countattwotrips.
•Tochang
etheswi
ngershutdowncount,select
(1‐6).
NOTE: Thisdefaultcanbechangedwithout
aff ectingSIACP‐01compliance.
Q-21 Select siren supervision time
(0-3)
DEFAULT: Disabled (0)
Thewiringconnectiontotheexternalsoundercan
besupervised.Ifthewiringtothesounderiscutfor
15,30,or45seconds,abelltroublereportcanbe
senttotheCentralStation.
•Thede
fault(0)disablesex
ternalsounder
supervision.
•Tosuper
visetheex
ternalsounderwiring,
select:
•(1)fo
r15sec
onds
•(2)for30sec
onds
•(3)for45sec
onds
Q-22 Enter CS lack of usage
notification time (0-255)
DEFAULT: Seven days (7)
InactivityreportscanbesenttotheCentralStation
ifthesystemhasnotbeenarmedforaperiodof
days.
•Thedefault(7)setsthelackofusag
efeatureat
sevendays.
•Tochang
ethelackofusag
efeatureduration,
select(1‐255)days.
•Toturnof
fthelackofusagefe
ature,select
disabled(0).