54 ©2013 2GIG Technologies Inc. All Rights Reserved.
Go!Control Wireless Security System | Install Guide
Q-78 Select output (00-10)
DEFAULT: Follows internal sounder
alarm (11) (Required SIA CP-01 Default)
Thesystem’ sopencollectoroutputisavailableon
theControlPanel’ sterminalblocktoconnecttoan
externaldevice.Theconditionsthatwillcausethe
opencollectoroutputtoactivateare
programmable.
•Selectoneactiv
ationoptio
nfortheControl
Panel’sopencollectoroutput:
(00)disabled
(01)activatedwhenarmed
(02)activatedwhendisarmed
(03)activatedonFTC(failuretocommunicate)
(04)activatedonsirensupervision
(05)activatedonradiofault
(06)activatedonburglaryalarm
(07)activatedonfirealarm
(08)activatedonanyalarm
(09)activatedonanysystemtrouble
(10)Z‐waveactivation(Option#10notcurrently
active)
(11)followsinternalsounderalarm
(12)followsexit/entrybeeps
Q-79 Select Z-Wave feature (0-3)
DEFAULT: Disabled but visible (1)
TheZ‐Wavehomeservicesfeaturecanbeenabled
ordisabledwithvariousremotecontrolaccess
options.
•Thedef
ault(1)display
stheServicesbutton,
butwillshowamessagethatthefeatureis
currentlydisabledandtheusershouldcallthe
installer.
•TohidetheService
sbu
tton,selectdisabled
andhidden(0).
•ToshowtheSer
vicesbuttonanddisableoff‐
siteremotecontrol,select(2).
•ToshowtheSer
vicesbutton,withZ‐Wave
rulesdisabledandoff‐siteremotecontrol
enabled,select(3).
Q-80 Select Z-Wave switches
feature (0-1)
DEFAULT: Disabled (0)
DisplayoftheHomeService’sSwitchesbuttoncan
beenabledordisabled.
NOTE: Thisprogrammingquestiononly
functionsiftheZ‐Wavefeatureenable
questionQ‐79issetto(2)or(3).
•Thede
fault(0)hidestheSw
itchesbutton.
•TodisplaytheSwi
tchesbutton,selectenabled
(1).
Q-81 Select Z-Wave thermostats
feature (0-1)
DEFAULT: Disabled (0)
DisplayoftheHomeService’sThermostatsbutton
canbeenabledordisabled.
ThisprogrammingquestiononlyfunctionsiftheZ‐
WavefeatureenablequestionQ‐79issetto(2)or
(3).
•Thede
fault(0)hidestheThermos
tatsbutton.
•TodisplaytheThermost
atsbutton,select
enabled(1).
Q-82 Select Z-Wave door locks
feature (0-1)
DEFAULT: Disabled (0)
DisplayoftheHomeService’sDoorlocksbuttoncan
beenabledordisabled.Thisprogrammingquestion
onlyfunctionsiftheZ‐Wavefeatureenable
questionQ‐79issetto(2)or(3).
•Thede
fault(0)hidestheDoorlock
sbutton.
•TodisplaytheDoorlocks
button,select
enabled(1).
Q-83 Select temperature display
units (0-1)
DEFAULT: Degrees Fahrenheit (0)
TheHomeService’sZ‐Wavethermostatdisplay
screenscanshowthetemperatureindegrees
FahrenheitordegreesCelsius.
NOTE: Thisprogrammingquestiononly
functionsiftheZ‐Wavefeatureenable
questionQ‐79issetto(2)or(3)andthe
thermostatfeatureisenabledwithQ‐81.
•Thede
fault(0)disp
laystemperaturein
degreesFahrenheit.
•Todisplaytemp
eratureindegreesCelsius,
select(1).
OpenCollectorOutputMode