Control Panel Programming Questions
©2013 2GIG Technologies Inc. All Rights Reserved.
51
hasbeenreachedorthesystemisdisarmed.If
alarmrestoresareenabledandswingershutdown
issettotwo,arestorewillbereportedifthesensor
isclosed(normalstate)atbellcutofforbecomes
closedafterbellcutoff.Ifswingershutdownisset
toone,arestorewillonlybesen
tifthesensoris
closedatthetimeofdisarm
.Restoresarenotsent
ifasensorisinswingershutdownuntilthetimeof
disarmandthesensorisclosed.
•Thedefault(0)preventsalarmrestorereports.
•Toallowalarmrestor
ereports,selectenabled
(1).
Q-58 Select trouble restore reports
to CS (0-1)
DEFAULT: Enabled (1)
TroublerestorereportscanbesenttotheCentral
Stationwhenanysensortroubleconditionclears.
•Thedefault(1)allowstr
oublerestorereports.
•Toturnofftroubleresto
rereports,select
disabled(0).
Q-59 Select bypass restores reports
to CS (0-1)
DEFAULT: Disabled (0)
BypassrestorereportscanbesenttotheCentral
Stationwhenanysensorthatwasforcebypassed
ormanuallybypassedgetsrestored.
•Thedef
ault(0)prev
entsbypassrestore
reports.
•Toallowbypa
ssrestorereports,selectenabled
(1).
Q-60 Select AC restore reports to
CS (0-1)
DEFAULT: Enabled (1)
ACpowerrestorereportscanbesenttotheCentral
StationwhentheControlPanelregainsACpower
afteranACpowerloss.
•Thedef
ault(1)allowsACpow
errestore
reports.
•Toturnof
fACpow
errestorereports,select
disabled(0).
NOTE: TheACpowerwillhavetoberestored
totheContr olPanelforoneminute
beforetheACpowerlosstroublealert
automaticallyclears.Ifprogramming
questionQ‐39isenabled,theactua
lAC
powerrestorereportwi lloccurata
randomtimeofuptofourhoursafterthe
ACpowerlosstroublealert
has
cleared.
NOTE: TheControlPanel’ sACpowericon
displaysthepowerstatus.Ared“X”over
theiconindicatesnoACpower.
Q-61 Select system low battery
restore reports to CS (0-1)
DEFAULT: Enabled (1)
ControlPanellowbatteryrestorereportscanbe
senttotheCentralStationiftheControlPanel
batteryhadtestedlowandisnowOk.
•Thede
fault(1)allowsCon
trolPanellow
batteryrestorereports.
•Toturnof
fCon
trolPanellowbatteryrestore
reports,selectdisabled(0).
Q-62 Select RF low battery restores
reports to CS (0-1)
DEFAULT: Enabled (1)
Sensorlowbatteryrestorereportscanbesentto
theCentralStationifasensorbatteryhadtested
lowandisnowOk.
•Thede
fault(1)allowssensorlowbat
tery
restorereports.
•Toturnof
fsensorlowba
tteryrestorereports,
selectdisabled(0).
Q-63 Select phone fail detect (0-1)
DEFAULT: Disabled (0)
Thesystemcanmonitorthetelephoneline
connectedtotheControlPanel.Ifthetelephone
lineisshortedorcut,theControlPanelwillindicate
telephonelinetroublebysoundingtroublebeeps
anddisplayingtheno‐phoneicon.
Iftheoptionalcellradiomodemisinstalled,the
telephonelinefailurewillstillbere
portedifthis
ques
tionisenabled.
•Thedefault(0)disablesth
isfeature.
•Toturnonthisfeat
ure,selectenabled(1).
NOTE: Ifthedialerisdisabledwith
programmingquestionQ‐8,telephone
linefailuredetectionisalsodisabled
regardlessofthesettingofthis
programmingquestion.