Control Panel Programming Questions
©2013 2GIG Technologies Inc. All Rights Reserved.
51
hasbeenreachedorthesystemisdisarmed.If
alarmrestoresareenabledandswingershutdown
issettotwo,arestorewillbereportedifthesensor
isclosed(normalstate)atbellcutofforbecomes
closedafterbellcutoff.Ifswingershutdownisset
toone,arestorewillonlybesen
tifthesensoris
closedatthetimeofdisarm
.Restoresarenotsent
ifasensorisinswingershutdownuntilthetimeof
disarmandthesensorisclosed.
•Thedefault(0)preventsalarmrestorereports.
•Toallowalarmrestor
ereports,selectenabled
(1).
Q-58 Select trouble restore reports
to CS (0-1)
DEFAULT: Enabled (1)
TroublerestorereportscanbesenttotheCentral
Stationwhenanysensortroubleconditionclears.
•Thedefault(1)allowstr
oublerestorereports.
•Toturnofftroubleresto
rereports,select
disabled(0).
Q-59 Select bypass restores reports
to CS (0-1)
DEFAULT: Disabled (0)
BypassrestorereportscanbesenttotheCentral
Stationwhenanysensorthatwasforcebypassed
ormanuallybypassedgetsrestored.
•Thedef
ault(0)prev
entsbypassrestore
reports.
•Toallowbypa
ssrestorereports,selectenabled
(1).
Q-60 Select AC restore reports to
CS (0-1)
DEFAULT: Enabled (1)
ACpowerrestorereportscanbesenttotheCentral
StationwhentheControlPanelregainsACpower
afteranACpowerloss.
•Thedef
ault(1)allowsACpow
errestore
reports.
•Toturnof
fACpow
errestorereports,select
disabled(0).
NOTE: TheACpowerwillhavetoberestored
totheContr olPanelforoneminute
beforetheACpowerlosstroublealert
automaticallyclears.Ifprogramming
questionQ39isenabled,theactua
lAC
powerrestorereportwi lloccurata
randomtimeofuptofourhoursafterthe
ACpowerlosstroublealert
has
cleared.
NOTE: TheControlPanel sACpowericon
displaysthepowerstatus.Ared“X”over
theiconindicatesnoACpower.
Q-61 Select system low battery
restore reports to CS (0-1)
DEFAULT: Enabled (1)
ControlPanellowbatteryrestorereportscanbe
senttotheCentralStationiftheControlPanel
batteryhadtestedlowandisnowOk.
•Thede
fault(1)allowsCon
trolPanellow
batteryrestorereports.
•Toturnof
fCon
trolPanellowbatteryrestore
reports,selectdisabled(0).
Q-62 Select RF low battery restores
reports to CS (0-1)
DEFAULT: Enabled (1)
Sensorlowbatteryrestorereportscanbesentto
theCentralStationifasensorbatteryhadtested
lowandisnowOk.
•Thede
fault(1)allowssensorlowbat
tery
restorereports.
•Toturnof
fsensorlowba
tteryrestorereports,
selectdisabled(0).
Q-63 Select phone fail detect (0-1)
DEFAULT: Disabled (0)
Thesystemcanmonitorthetelephoneline
connectedtotheControlPanel.Ifthetelephone
lineisshortedorcut,theControlPanelwillindicate
telephonelinetroublebysoundingtroublebeeps
anddisplayingthenophoneicon.
Iftheoptionalcellradiomodemisinstalled,the
telephonelinefailurewillstillbere
portedifthis
ques
tionisenabled.
•Thedefault(0)disablesth
isfeature.
•Toturnonthisfeat
ure,selectenabled(1).
NOTE: Ifthedialerisdisabledwith
programmingquestionQ8,telephone
linefailuredetectionisalsodisabled
regardlessofthesettingofthis
programmingquestion.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the 2gig Technologies Go Control and is the answer not in the manual?

2gig Technologies Go Control Specifications

General IconGeneral
Brand2gig Technologies
ModelGo Control
CategorySecurity System
LanguageEnglish

Related product manuals