EasyManuals Logo

2gig Technologies Go Control User Manual

2gig Technologies Go Control
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #49 background imageLoading...
Page #49 background image
48 ©2013 2GIG Technologies Inc. All Rights Reserved.
Go!Control Wireless Security System | Install Guide
•EnterfourdigitsfortheCentralStation#2
accountnumber.
•TheShiftbutto
naccessesB,C,D,E,andF
characters.
Q-42 Select remote control phone
(0-3)
DEFAULT: Data and voice (3)
Thissettingcontrolsremotetelephoneaccessto
thesystem.Thedataoptionisfortheinstaller.It
allowsaccessforprogrammingandoperatingthe
systemwithcustomPCdownloadersoftware.
Thevoiceoptionisforthesubscriber.Itallowsthe
subscribertocallthesystemfromanoffsite
phone,togetthesta
tusofthesys
tem,andto
performremotecommands.Thesecommandsare
executedbyenteringtouchtones.Thestatusis
reportedbackviavoiceprompts.AvalidUserCode
isrequiredforremotetelephoneaccess.Theuser
willbeabletoperformthefollowingfunctions:arm
inanymode,di
sarm,bypass,getsy
stemstatus,and
turnonorturnofftheopencollectoroutput.
Ifvoiceaccessisenabled,toconnecttothepanel,
thesubscriberwillneedtocallthetelephone
numberthattheControlPanelisconnectedto,
waitforoneortworings,thenhangup.The
sub
scrib
erneedstocallagain,within1045
seconds.TheControlPanelanswersthecall.
Whenthepanelanswersthephone,theuserwill
bepromptedtoentertheircode.Ifavalidcodeis
entered,thesystemwillannouncethecurrent
systemstatus.Ifaninvalidcodeisentered,the
pa
ne
lwillaskforthecodeagain.Aftertwoinvalid
attempts,thepanelwilldisconnect.Aftertwocalls,
withtwoinvalidattemptseach,thepanelwilllock
out.Thelockoutwilllastfor30minutes.
•Thedef
ault(3)enab
lesdataandvoiceaccess.
•Fordataonlyacce
ss,select(1).
•Forvoiceacce
ssonly,select(2).
•Todisableremo
teaccess,select(0).
(0)disabled(noremotecontrolphone)
(1)dataonly
(2)voiceonly
(3)dataand
voice
NOTE: RemotelyarmingthesystemtoAway
ModewillnotstartanExitDelayor
activateAutoStayMode(ifenabled).
Q-43 Enter installer code (4 digits)
DEFAULT: 1561
TheInstallerCodeisthecoderequiredtoenterthe
InstallerToolbox.
•ThedefaultfortheIns
tallerCodeis1561.
•TochangetheInst
allerCode,enteranew4
digitcode.
BESURETOWRITEDOWNTHENEWCODE!
NOTE: TheInstallerCodemustbeuniquefrom
anyUserCodes.
Q-44 Select lock installer
programming (0-2)
DEFAULT: Disabled (0)
Theinstallerprogramminglockoutfeatureis
providedtopreventtakeovers.TheControlPanel
canbesettolimitaninstallersaccessto
programmingquestionsafteraperiodof48hours.
The48hourlockouttimerstartswhentheinstaller
exitssystemconfigurationmode.Threeoptionsare
available:
unlimitedful
laccess
toprogramming(no
lockout)
•limitedacce
sstoprogr
ammingafter48hours
•noaccesstoprogr
ammingafter48hours
Thedefault(0)selectsunlimitedfullaccessto
programming(nolockout).
Todenyaccesstoprogrammingafter48hours,
selectnoaccesstoprogramming(1).
Toselectlimitedaccesstoprogrammingafter48
hours,select(2).Afterthesystemhasrunfor48
hours,installerwillbeabletoview,butnotchang
e,
theCent
ralStationphonenumber,CentralStation
accountnumber,lockinstallerprogramming,
downloadID,anddefaultlockoutfields.
Afterthe48hourlockouttimerhaslock edoutthe
system,thetimercanberesetthroughthecell
radioorPCdownloaderbyremotelysettingthis
questionQ44to(0)or(2
).Settingtheoptio
nto(0)
or(2)willrestartthe48hourlockouttimer.
RemoteControlPhoneMode
TelephoneKey RemoteControlPhoneMode
1 Systemstatusreport
2ArmthesysteminAwayMode
3 ArmthesysteminStayMode
4Disarmthesystem
5 Turnontheauxiliaryoutput
6Turnofftheauxiliaryoutput
7 Stopthesystemstatusreport
8 Disconnect(hangup)
9 Repeatcommandmenu
#Bypassallopensensorsandarmsystem
TelephoneKey RemoteControlPhoneMode

Table of Contents