EasyManuals Logo

2gig Technologies Go Control User Manual

2gig Technologies Go Control
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #24 background imageLoading...
Page #24 background image
Programming Navigation
©2013 2GIG Technologies Inc. All Rights Reserved.
23
3 EntertheInstallerCode(default=1561)to
displaytheInstallerToolbox.
4 PressSystemConfigurationandbegin"RF
SensorProgrammingStep
s"onpage30.
5 Usetheinstallationlogsheettorecord
programmedoptionsforthesystem.
6 Aftersettingalltherequiredprogramming
valuesforthesensorsandtheControlPanel,
pressEnd,thenExit,tosavethechanges.
7 AftertheControlPanelrestarts,pressSecurity
/Menu/Toolbox,entertheMasterUserCode
(default=1111),pressUserManagementand
setuptheuserscodes.BesuretosetaDuress
CodeasUser#8.PressBackwhenfinished.
8 PressBrightness/Volumeandsetthelevelsfor
theinstallation.
9 Thevolumesettingdoesnotaffectthevolume
ofalarmsounds.
10 Press→toviewthesecondtoolboxscreen.
11 PressBackLightTimeoutandsetthedisplay
lightingtimeout.
12 PressSetDat eandSetTimeandsetthe
calendarandclock.IftheCellRadioModuleis
installed,thedateandtimesetsautomatically.
13 Pressthe buttontoreturntotheHome
Screen.
Aftercompletingallsetupand
programming,refer
totheUserGuidefordetailsonoperatingthe
system.Checkofftheprogrammedoptionsforthe
systemintheUserGuide.
NOTE: Besuretoinstructthesubscriberon
theproperoperationofthesystem,and
leavetheUserGuideattheinstallation
siteforreference.
SIA CP-01 Defaults
Severalsystemprogrammableoptionshavethe
defaultspresettoprovidecompliancewiththe
SecurityIndustryAssociationCP01Standard.All
othersystemsettingsandfunctionsthatare
requiredtocomplywithSIACP01ar epermanently
programmedintotheConsoleandcannotbe
changed.Refertothetableforeachpr
ogrammable
optionthathasareq
uiredSIACP01programming
default.
ProgrammingQuestion SIACP01Default Range
Q1WirelessSensorDialerDelay 30Seconds OnorOff
Q2WiredSensorDialerDelay 30Seconds OnorOff
Q5ExitDelay 60Seconds 45120Seconds
Q6EntryDelay#1 30Seconds 30240Seconds
Q7EntryDelay#2 45Seconds 30240Seconds
Q10CallWaitingDisableCode NoDefaultCode 06Digits
Q20SwingerShutdownCount 2Trips 16Trips
Q26AutoStay Enabled EnabledDisabled
Q27ExitDelayRestart Enabled EnabledorDisabled
Q31CancelTime 5Minutes 6254Minutes
Q32CancelDisplay Enabled EnabledorDisabled
Q35AbortWindowDialerDelay 30Seconds 15or45Seconds
Q79SelectOutput FollowsInternalSounder SeeQ78forOptions

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the 2gig Technologies Go Control and is the answer not in the manual?

2gig Technologies Go Control Specifications

General IconGeneral
Brand2gig Technologies
ModelGo Control
CategorySecurity System
LanguageEnglish

Related product manuals