Years from start-upMaintenance task/object
1211109876543210
Cooling
RInverter module main cooling fan
RFrame R5i auxiliary cooling fan
RFrame R8i circuit board compartment fan
RCabinet cooling fan (50 Hz)
RRCabinet cooling fan (60 Hz)
Batteries
RRControl unit battery
RControl panel battery
Connections and environment
IIIIIIIIIIIIIAir inlet and outlet cleaning (IP20/IP42)
RRRRRRRRRRRRRCabinet door filter change (IP54)
IIIIIIIIIIIIIChecking tightness of cable and busbar termin-
als. Tightening if needed.
IIIIIIIIIIIIIChecking ambient conditions (dustiness, corro-
sion, temperature)
IIIIIIIIIIIIICleaning of heatsinks
PPPPPPPPPPPPPQuality of supply voltage
Spare parts
IIIIIIIIIIIIISpare parts
PPPPPPPPPPPPPDC circuit capacitor reforming (spare modules
and spare capacitors)
4FPS10000292961
Symbols
Inspection (visual inspection and maintenance action if needed)I
Performance of on/off-site work (commissioning, tests, measurements or other work)P
ReplacementR
Maintenance and component replacement intervals are based on the assumption that the
equipment is operated within the specified ratings and ambient conditions. ABB recommends
annual drive inspections to ensure the highest reliability and optimum performance.
Note:
Long term operation near the specified maximum ratings or ambient conditions may require
shorter maintenance intervals for certain components. Consult your local ABB Service
representative for additional maintenance recommendations.
Maintenance timers and counters
The control program has maintenance timers and counters that can be configured to generate
a warning when a pre-defined limit is reached. Each timer/counter can be set to monitor
any parameter. This feature is especially useful as a service reminder. For more information,
see the firmware manual.