Refitting the base cover (-10/1.52 and -12/1.27)
NoteAction
3HAC061327-072Wipe, lubricate and fit the o-ring to its groove.1
Grease: 3HAC042536-001 (Shell
Gadus S2)
Replace if damaged.
xx2000002016
Hex socket head cap screw: M3x8
12.9 Lafre 2C2B/FC6.9 (8 pcs)
Refit the bottom cover with the attachment screws.
Note
For CRB 15000-5/0.95, fit the cover in correct dir-
ection, the protrusion of the cover must face out-
wards.
2
Tightening torque: 1.4 Nm.
xx2300000760
Securing the base
NoteAction
Attachment screws: M10x35 8.8 (4
pcs).
Lift the base to standing and secure it to the
foundation with the attachment screws and
washers.
1
Washers: 23/10.5/2.5 mm Steel (4
pcs).
Tightening torque: 32 Nm ±10%.
xx2000002006
Continues on next page
278 Product manual - CRB 15000
3HAC077389-001 Revision: L
© Copyright 2021 - 2023 ABB. All rights reserved.
5 Repair
5.3.2 Replacing the axis-1 cabling
Continued

Table of Contents