Removing the axis-2 joint unit (-5/0.95)
NoteAction
Lifting aid: 3HAC077788-001Fit the lifting aid to the joint unit, on the torque
sensor side.
CAUTION
The connectors and the joint unit cables are
sensitive to mechanical damage. Handle the as-
sembly with care.
1
Screws: M4x35 (4 pcs)
xx2000001956
xx2100000295
Remove two attachment screws.
Dispose the screws.
New screws are included in the spare part delivery
of the joint unit.
2
Guide pin, M4x120: 3HAC077786-
001
Fit two guide pins to the axis-2 joint unit.3
Always use guide pins in pairs.
For joint units on axes 1, 2 and 3
of CRB 15000-5/0.95 and axis 3 of
CRB 15000-10/1.52 and CRB
15000-12/1.27.
xx2000002433
xx2000001943
Remove the remaining attachment screws.
Use two screws as press out screws in the upcom-
ing step, then dispose all screws.
New screws are included in the spare part delivery
of the joint unit.
4
Continues on next page