NoteAction
xx2000002082
Lift the tubular into mounting position while insert-
ing the cabling into the housing.
3
Slide the tubular into place on the guide pins.4
Flange socket head screw: M3x20
12.9 Lafre 2C2B/FC6.9+PrO-
COat111
Secure the tubular to the housing with all attach-
ment screws but two.
Pre-tighten the screws crosswise firstly.
5
xx2000002081
Flange socket head screw: M3x20
12.9 Lafre 2C2B/FC6.9+PrO-
COat111
Remove the guide pins and fasten the remaining
two screws.
6
xx2000002079
Tightening torque: 1.8 Nm.Torque tighten all screws crosswise.7
Continues on next page
590 Product manual - CRB 15000
3HAC077389-001 Revision: L
© Copyright 2021 - 2023 ABB. All rights reserved.
5 Repair
5.4.3 Replacing the tubular
Continued