Removing the swing (-5/0.95)
Use these procedures to remove the swing.
Preparations before removing the swing
NoteAction
xx2100000044
Jog the robot to the specified position: xxx
• Axis 1: 0°
• Axis 2: 0° (home position)
• Axis 3: +60°
• Axis 4: 0°
• Axis 5: -90°
• Axis 6: No significance.
CAUTION
Jog the axis on which the joint unit is to be re-
placed to home position, to achieve correct cable
routing during replacement of the joint unit.
1
DANGER
Turn off all:
• electric power supply
• hydraulic pressure supply
• air pressure supply
to the robot, before entering the safeguarded
space.
2
Removing the lower arm covers (-5/0.95)
NoteAction
CAUTION
Make sure that all supplies for electrical power
are turned off.
1
Continues on next page
Product manual - CRB 15000 721
3HAC077389-001 Revision: L
© Copyright 2021 - 2023 ABB. All rights reserved.
5 Repair
5.5.2 Replacing the swing