Connecting the axis-2 joint unit cabling
NoteAction
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling
the unit read the safety information in section
The unit is sensitive to ESD on page 53.
1
xx2000002013
Reconnect the connectors to the drive board.
• D2.X1 to X1
• D2.DC+ to DC+
• D2.DC- to Ground
• D2.X4 to X4
• D2.X2 to X2
• D2.X5 to X5
2
xx2000001944
Connect the connectors to each other and snap
them to the cable holders.
• J2.DC+ to J2.DC+
• J2.DC- to J2.DC-
• J2.CS to J2.CS
• J2.CP to J2.CP
3
Hex socket head cap screw: M3x6 (1
pcs).
Secure the cables for functional earth and
protective earth with a screw.
4
Tightening torque: 0.8 Nm.
xx2000001945
Continues on next page
Product manual - CRB 15000 897
3HAC077389-001 Revision: L
© Copyright 2021 - 2023 ABB. All rights reserved.
5 Repair
5.6.4 Replacing the axis-2 joint unit (CRB 15000-10/1.52 and CRB 15000-12/1.27)
Continued