NoteAction
The capacity of the vessel must be suffi-
cient to take the complete amount of oil.
xx1800001138
Valid for IRB 2600-20/1.65, IRB 2600-
12/1.65, IRB 2600-12/1.85, IRB 2600ID-
15/1.85, IRB 2600ID-8/2.0:
Put an oil collecting vessel as close
as possible to the draining hole of
the gearbox.
Replace oil plug draining quickly with
a nipple (M10x1.5) where a draining
hose is fitted and connect the oil
dispenser.
5
Note
Draining is time-consuming.
Elapsed time varies depending on the
temperature of the oil.
One example of oil dispenser can be
found in section:
Type of lubrication in gearboxes on
page 148
Different position due to design differ-
ences:
xx1800001137
Remove the plug from the vent hole.
WARNING
If the oil plug for venting is not open when
the oil dispenser is working, there is a risk
of damaging vital parts in the gearbox!
6
xx1800001139
Suck out the oil with the oil dispenser.
Note
There will be some oil left in the gear after
draining.
7
Continues on next page
Product manual - IRB 2600 153
3HAC035504-001 Revision: Q
© Copyright 2009-2018 ABB. All rights reserved.
3 Maintenance
3.4.2 Changing the oil, axis 1 gearbox on floor mounted robots
Continued

Table of Contents

Related product manuals