NoteAction
WARNING
Used oil is hazardous material and must be
disposed of in a safe way. See section De-
commissioning on page 423 for more inform-
ation.
8
Remove the oil dispenser.9
xx1800001136
Valid for IRB 2600 Type C-20/1.65, IRB
2600 Type C-12/1.65:
Refit the protective cap on the nipple.
10
Tightening torque: 3-8 Nm
xx1800001138
Valid for IRB 2600-20/1.65, IRB 2600-
12/1.65, IRB 2600-12/1.85, IRB 2600ID-
15/1.85, IRB 2600ID-8/2.0:
Refit the oil plug, draining.
Note
Before refitting the oil plug in the gearbox,
always replace the oil plug gasket with a
new gasket. If not there is a risk of leakage.
11
Continues on next page
154 Product manual - IRB 2600
3HAC035504-001 Revision: Q
© Copyright 2009-2018 ABB. All rights reserved.
3 Maintenance
3.4.2 Changing the oil, axis 1 gearbox on floor mounted robots
Continued