InformationAction
Grease: Shell Gadus S2V220 AC,
3HAB3537-1.
xx1000001005
Place the cable harness spiral into its pos-
ition in the arm house.
Lubricate the cables in the spiral with
grease.
Note
Do not cut the strap used as transport
protection of the cable harness spiral at
this point!
2
Parts:
A Cable harness spiral
B Attachment screws (8 pcs) M8x25
quality Steel 12.9 Gleitmo
xx1000001006
Apply flange sealant on the surface where
the cover shall be fitted. See figure!
3
Part:
A Flange sealant: Loctite 574,
12340011-116
Continues on next page
228 Product manual - IRB 2600
3HAC035504-001 Revision: Q
© Copyright 2009-2018 ABB. All rights reserved.
4 Repair
4.3.3 Replacing the cable harness in the upper arm - IRB 2600ID
Continued