Required documents
NoteArticle numberDocument
3HAC059896-009,
3HAC063898-009,
3HAC072448-009
Circuit diagram - OmniCore C30,
Circuit diagram - OmniCore C30
for IRB 14050, Circuit dia-
gram - OmniCore C30 for CRB
15000
Installing the harness double SMB
Preparations
Note/IllustrationAction
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see Electrical safety on
page 31.
1
Location of wrist strap button:
xx1800000683
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 47.
2
See Removing the controller covers on
page 222.
Remove the front panel and top cover.3
Removing the axis computer from the cabinet
Note/IllustrationAction
Disconnect:
• K6.X11 - A1.X3
• K6.X2 - A2.X9
• K6.X1 - K2.X3.
1
Continues on next page
Product manual - OmniCore C30 137
3HAC060860-001 Revision: P
© Copyright 2019-2022 ABB. All rights reserved.
3 Installation and commissioning
3.7.1 Installing the harness for double SMB
Continued