Removing the small fan
Note/IllustrationAction
xx1800000479
Remove the screws holding the fan.1
xx1800000480
Push and slide the fan bracket and lift it
out.
2
Disconnect:
G2.X1-K2.X17
3
Removing the main computer assembly with process plate
Note/IllustrationAction
Disconnect all the connectors on the as-
sembly group of the robot signal ex-
change proxy, Ethernet switch (option),
connected services gateway, scalable
I/O (option), and main computer.
1
Continues on next page
Product manual - OmniCore C30 155
3HAC060860-001 Revision: P
© Copyright 2019-2022 ABB. All rights reserved.
3 Installation and commissioning
3.7.4 Installing the power supply optional device and the harness 24 V extension