A
B B
B B
xx1800000532
xx1900000215
Screws holding the scalable I/O
bracket (1 pcs)
A
Screws holding the process plate (4
pcs)
B
Remove the screws holding the process
plate and the screws holding the scalable
I/O bracket.
3
Pull out the process plate with the as-
sembly from the two guide pins on the
mounting plate.
Note
Avoid colliding with the frame when re-
moving the unit.
4
Continues on next page
174 Product manual - OmniCore C30
3HAC060860-001 Revision: P
© Copyright 2019-2022 ABB. All rights reserved.
3 Installation and commissioning
3.7.5 Installing the fieldbus master and the DeviceNet harness
Continued