5.2.3.1.1 Replacing the standard fan
Removing the standard fan
Preparations
Note/IllustrationAction
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see Electrical safety on
page 31.
1
Location of wrist strap button:
xx1800000683
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 47.
2
Removing the controller covers on page 222.Remove the top and right covers of the
controller.
3
Removing the standard fan
Note/IllustrationAction
Disconnect standard fan:
G1.X2-K2.X17
1