Refitting the robot signal exchange proxy
Note/IllustrationAction
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see Electrical safety on
page 31.
1
Location of wrist strap button:
xx2000000532
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 47.
2
Screws: Torx pan head screw M4x8 (4 pcs)
xx1800000489
Fit the robot signal exchange proxy and
secure the screws.
Note
Avoid colliding with the frame of the
controller.
3
xx1800000971
Insert the cable ties into the locking
holes.
4
Continues on next page
Product manual - OmniCore C30 277
3HAC060860-001 Revision: P
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.2.3.3 Replacing the main computer fan
Continued