Removing the power supply optional
Note/IllustrationAction
Disconnect:
• A1.X7 - T5.X1
1
xx1800000549
Remove the attachment screws and lift
the power supply out.
2
Disconnect:
• T5.X2 - X45
3
Removing the motor connector
Note/IllustrationAction
Disconnect the following connectors for
the motor connector:
• T4.X7, T4.X8, T4.X9
• X1 - K2.X7 & X22
• Two ground cables which con-
nects on the left side of the cabin-
et frame.
1
Continues on next page
Product manual - OmniCore C30 419
3HAC060860-001 Revision: P
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.3.2.1 Replacing the motor connector
Continued