Note/IllustrationAction
Location of wrist strap button:
xx1800000683
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 47.
2
Insert the incoming mains connector into
the front panel from inner side of the
cabinet.
3
Screws: Torx, countersunk screw M4x10 (4
pcs)
xx1800000734
Secure it with the screws.4
Reconnect:
• Q0 - A1.X1.
• Two ground cables which con-
nects to the left cabinet frame.
5
Refitting the axis computer to the frame
Note/IllustrationAction
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see Electrical safety on
page 31.
1
Continues on next page
Product manual - OmniCore C30 437
3HAC060860-001 Revision: P
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.3.3 Replacing the incoming mains connector
Continued