Removing the HMI signal connector
Note/IllustrationAction
Remove the cables out from the clips in
the bottom of the cabinet carefully.
Note
Make records about the sequence that
cables are removed. The cables need to
be installed in the same position.
1
xx1800000735
Remove the attachment screws on the
front panel.
2
Push the HMI signal connector into the
cabinet.
3
Push the cables on HMI signal connector
out from the clips on the bottom of the
cabinet.
4
Take the HMI signal connector out from
the upper side.
5
Refitting the HMI signal connector
Refitting the HMI signal connector
Note/IllustrationAction
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see Electrical safety on
page 31.
1
Continues on next page
446 Product manual - OmniCore C30
3HAC060860-001 Revision: P
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.3.4 Replacing the HMI signal (FlexPendant) connector
Continued