Note/IllustrationAction
Location of wrist strap button:
xx1800000683
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 47.
2
Screws: Torx, countersunk screw M4x10 (4
pcs)
xx1800000736
Insert the HMI signal connector into the
front panel from inside the cabinet.
Secure it with the screws.
3
xx1900001007
Insert the cables on HMI signal connector
into the clips on the bottom of the cabin-
et.
Tip
Use the same position as from removing
HMI connector.
4
Continues on next page
Product manual - OmniCore C30 447
3HAC060860-001 Revision: P
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.3.4 Replacing the HMI signal (FlexPendant) connector