Removing the IP20 power outlet connector
Note/IllustrationAction
Disconnect:
• X45 - T5.X2.
1
Push the cables out from the clips in the
bottom of the controller carefully.
Note
Make records about the sequence that
cables are removed. The cables need to
be installed in the same position.
2
Disconnect the power supply optional.3
xx1800000741
Remove the attachment screws on the
front panel.
4
Push the IP20 power outlet connector
into the cabinet.
5
Push the cables on IP20 power outlet
connector out from the clips on the bot-
tom of the cabinet.
6
Take the IP20 power outlet connector out
from the upper side.
7
Refitting the IP20 power outlet connector
Refitting the IP20 power outlet connector
Note/IllustrationAction
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see Electrical safety on
page 31.
1
Continues on next page
482 Product manual - OmniCore C30
3HAC060860-001 Revision: P
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.3.7 Replacing the IP20 power outlet connector
Continued