Note/IllustrationAction
Location of wrist strap button:
xx1800000683
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 47.
2
Insert the IP20 power outlet connector
into the front panel from inside the cabin-
et.
3
Screws: Torx, countersunk screw M4x10 (2
pcs)
xx1800000742
Secure it with the screws.4
Reconnect the power supply optional.5
xx1900001006
Insert the cables on IP20 power outlet
connector into the clips in the bottom of
the cabinet.
Tip
Use the same position as from removing
IP20 power outlet connector.
6
Reconnect:
• X45 - T5.X2.
7
Continues on next page
Product manual - OmniCore C30 483
3HAC060860-001 Revision: P
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.3.7 Replacing the IP20 power outlet connector
Continued