Note/IllustrationAction
For the robot signal exchange proxy:
• K2.X8 - A2.X6
• (option): K2.X2 - K4.X8, A2.X1
• K2.X12 - A2.K3.X6, A2.K3.X7
• K2.X10 - A1.X13
• K2.X21 - TempSensor
• K2.X4 - A1.X9
• K2.X3 - K6.X1, A2.K3.X1, K5.1.X4,
K7.X1
• K2.X1 - T2.X2
53
• K2.X1 - X107
54
• K2.X17 - G2.X1, G1.X2
• K2.X6, K2.X11 - A1.X2
• K2.X7, K2.X22 - Harn. LV robot
power
• K2.X9 & X13 - FlexPendant
For the Ethernet extension switch (op-
tion):
• K2.X2 - K4.X8, A2.X1
• A2.X4 - K4.X6
Note
When Ethernet extension switch
is selected, connect and discon-
nect the connector A2.X4) to/from
K4.X6.
• Harness adapter - A2.X4/K4.X7.
Note
When Ethernet extension switch
is selected, connect and discon-
nect the adapter cable (Adapter -
A2.X4/K4.X7) to/from K4.X7.
For the connected services gateway:
• K7.X1 - K2.X3
i
• K7.X2 - A2.X5
Note
The connector K7.X2 is locked;
grab the connector, push it in to
release it and then remove the
connector.
Continues on next page
486 Product manual - OmniCore C30
3HAC060860-001 Revision: P
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.3.7 Replacing the IP20 power outlet connector
Continued