SignificanceDescription
Automatic Stop/General Stop LED can
be used to identify the following status:
No color (not lit): Automatic
Stop/General Stop input loop is
open.
Green, solid: Automatic
Stop/General Stop input loop is
closed.
Automatic Stop/General Stop LEDs
(green)
AS1/GS1:Automatic Stop/General Stop
LED channel 1
AS2/GS2:Automatic Stop/General Stop
LED channel 2
AS1/GS1
&
AS2/GS2
External emergency stop LED can be
used to identify the following status:
No color (not lit): External emer-
gency stop input loop is open.
Green, solid: External emergency
stop input loop is closed.
External emergency stop LEDs (green)
ES1:External emergency stop LED
channel 1
ES2:External emergency stop LED
channel 2
ES1 &
ES2
Emergency stop output LED can be used
to identify the following status:
No color (not lit): Emergency stop
output is in State 0 (0V) status.
Green, solid: Emergency stop
output is in State 1 (24V) status.
Emergency stop output LEDs (green)
ES1:Emergency stop output LED chan-
nel 1
ES2:Emergency stop output LED chan-
nel 2
ES-
OUT1
& ES-
OUT2
Motors_ON LED can be used to identify
the following status:
No color: Motors_ON function is
off.
White, solid: Motors_ON function
is on.
White, flashing: safety loop is
open, for example after an emer-
gency stop.
Motors_ON LED (white)MON
ACOK LED can be used to identify the
following status:
No color: AC OK signal is de-act-
ive or logic power failure.
Green, solid: AC OK signal is act-
ive and logic power available.
ACOK LED (green)AC
Internal power input LED can be used to
identify the following status:
No color: Internal power input
voltage is not in normal range.
Green, solid: Internal power input
voltage is in normal range.
Internal power (24 V power supply) input
LED (green)
PS
Main computer power output LED can be
used to identify the following status:
No color: Main computer power
output voltage is not in normal
range.
Green, solid: Main computer power
output voltage is in normal range.
Main computer power output LED (green)PC
FlexPendant power output LED can be
used to identify the following status:
No color: FlexPendant power out-
put voltage is not in normal range.
Green, solid: FlexPendant power
output voltage is in normal range.
FlexPendant power output LED (green)HMI
Continues on next page
Product manual - OmniCore C30 557
3HAC060860-001 Revision: P
© Copyright 2019-2022 ABB. All rights reserved.
6 Troubleshooting
6.3.11 Troubleshooting the robot signal exchange proxy
Continued