EasyManua.ls Logo

ABB OmniCore C30 - Page 70

ABB OmniCore C30
606 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
InformationAction
BDAC
xx1700001883
Front mounting kitA
Back mounting kitB
Torx pan head screw M4x12 (4 pcs)
Tightening torque: 1.7-1.8 Nm
C
Torx countersunk screw M4x10 (5
pcs)
Tightening torque: 1.7-1.8 Nm
D
Assemble the front and the back mounting
kit.
2
xx1700001884
Place the controller into the 19" cabinet and
fasten it with the screws.
3
Torx pan head screw M6x16 (4 pcs)
Tightening torque: 1.7-1.8 Nm
The antenna is preferably placed on top
of the cabinet.
Note
For best performance in a closed cabinet,
use the option Connected Services
Gateway wired (DSQC1041) with external
Internet gateway.
Connect the antenna for Connected Services
Gateway (3G or WiFi).
4
70 Product manual - OmniCore C30
3HAC060860-001 Revision: P
© Copyright 2019-2022 ABB. All rights reserved.
3 Installation and commissioning
3.4.4 Replacing the controller from vertical mounting kit to19" rack mounting kit
Continued