Info/illustrationAction
xx1800000459
Torx countersunk screw M3x6 (6 pcs)
Tightening torque: 0.6-0.8 Nm
Place the controller upright and install the
right and left cover unit. Lock them with
screws on the bottom side and connect the
cables.
K2.X15.3
K2.X15.4
X4
Note
Do not hold the TPU connector (X4)
during any moving or transporting of
the controller.
MGMT
4
K2.X15.3
K2.X15.4
xx1800000460
xx1800000461
Keep the controller upright. Connect the
adapter cables to the front cover unit, and
install the front cover unit.
5
The antenna can be placed on top of the
controller.
Connect the antenna for Connected Services
Gateway (3G or WiFi).
6
Continues on next page
Product manual - OmniCore C30 73
3HAC060860-001 Revision: P
© Copyright 2019-2022 ABB. All rights reserved.
3 Installation and commissioning
3.4.5 Mounting the controller with desktop mounting kit [3001-2]
Continued