Note/illustrationAction
xx1900000049
Crimp the contact sockets (support
cross-section from 0.35-2.5mm
2
) to the
cable with the four-indent crimping tool
which follows the MIL-C-22520/1-01
standard at position A.
Tip
Make sure that the cross-section value
for the wire you select is within the limit-
ation of the tool you use.
7
Cut the extra wire fillers.8
xx1900000050
Press the shielding element to the crown
clamp.
Tip
The installation is ok when you hear a
"click" sound.
9
xx1900000051
Cut off the extra shielding copper wires
of the cable if needed.
10
Twist the crown clamp to secure it.11
xx1900000052
Open the insulation inserts for about 2
mm by pulling it apart.
12
xx1900000055
Insert the contact sockets into insulation
inserts.
13
Close the insulation inserts.
Tip
The installation is ok when you hear a
"click" sound.
14
Continues on next page
Product manual - OmniCore C30 95
3HAC060860-001 Revision: P
© Copyright 2019-2022 ABB. All rights reserved.
3 Installation and commissioning
3.5.4 Fitting the connector
Continued