Installing the additional drive unit
Note/IllustrationAction
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see Electrical safety on
page 29.
1
Location of wrist strap button:
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 45.
2
xx2200001817
Screws: Torx pan head screw M4x8 (4 pcs)Fit the additional drive unit and secure
with the screws.
3
Tightening torque: 2 Nm
xx2200001375
Connect:
T4.X7 -X12, T4.X15
T4.X17 - A1.X2
T4.X13 - A1.X11
T4.X5 - A1.X4
T4.X3 - A1.X12
T4.X1 - A1.X5
4
Continues on next page