5.5 Replacing other parts
5.5.1 Replacing the motor connection box
Location
The motor connection box location is decided by the customer.
Required spare parts
Note
The spare part numbers that are listed in the table can be out of date. See the
latest spare parts of the OmniCore V250XT Type B via myABB Business Portal,
www.abb.com/myABB.
NoteArticle numberSpare part
3-axis, BRB3HAC087718-001Motor Connection Box
6-axis, BRB3HAC087720-001Motor Connection Box
Required tools and equipment
NoteArticle numberEquipment
Content is defined in section
Standard toolkit for controller on
page 426.
-Standard toolkit
-ESD protective wrist band
Required documents
NoteArticle numberDocument
3HAC074000-008Circuit diagram - OmniCore
V250XT, rev 04 or later
Removing the motor connection box
Note/IllustrationAction
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see Electrical safety on
page 29.
1
Disconnect all connectors from the unit
to be replaced.
2
Continues on next page
330 Product manual - OmniCore V250XT Type B
3HAC087112-001 Revision: A
© Copyright 2023-2023 ABB. All rights reserved.
5 Repair